Amana PTH093G50AXXX 规格说明表单

下载
页码 8
P
roduct
 S
PecificationS
4
www.amana-ptac.com
SS-DPTAC
P
roduCT
 s
PeCifiCATions
:  PTH m
odels
 — C
ooling
/H
eAT
 P
umP
/e
leCTriC
 H
eAT
Model ¹
,
 
6,
 
8,
 
9
PTH073G 
**AXXX
PTH093G 
**AXXX
PTH123G 
**AXXX
PTH153G 
**AXXX
PTH074G 
**AXXX
PTH094G 
**AXXX
PTH124G 
**AXXX
PTH154G 
**AXXX
Voltage ¹
,
 ³
230 / 208
230 / 208
230 / 208
230 / 208
265
265
265
265
Capacity (BTU/h)
7,600
9,000
12,000
14,200
7,600
9,100
12,000
14,200
Amps ¹⁰
3.9
4.2 / 4.2
5.8 / 5.8
7.0 / 7.0
3.1
3.7
5.0
6.1
Watts ¹⁰
650 
785
1,120 / 1,120
1,465 / 1,465
650
790
1,120
1,465
EER
11.7 / 11.7
11.5 / 11.5
10.7 / 10.7
9.7 / 9.7
11.7
11.5
10.7
9.7
Unit without Electric Heater
Min. Circuit Amps ²
,
 ⁴
,
 ¹⁰
4.7
5.1
7.1
8.5
3.8
4.5
6.1
7.4
CFM (Cool/Wet Coil)
High
340
330
340
390
340
330
340
390
Low
245
245
245
340
245
245
245
340
CFM (Dry Coil)
High
370
360
370
410
370
360
370
410
Low
270
270
270
370
270
270
270
370
Ventilated Air, CFM (Fan Only)*
65*
65*
65*
65*
65*
65*
65*
65*
Ventilated Air, CFM (Comp & Fan)*
40*
40*
40*
40*
40*
40*
40*
40*
Dehumidification (Pints/Hr.)
1.7
2.2
3.6
4.4
1.7
2.2
3.6
4.4
Net Weight (lbs.)
108
112
115
126
108
112
115
125
Ship Weight (lbs.)
123
127
132
143
123
127
132
142
* Actual vent CFM performance will vary due to application and installation conditions.
Notes
¹    All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
²    Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.   
Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
³    Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.
⁴    Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay 
fuses (included and factory-installed on all Amana® brand 265-volt chassis).
⁵    Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F 
outdoor ambient.
⁶    Specify two-digit heater kW size to complete model number.
⁷    R-410A refrigerant used in all systems.
⁸    All units meet or exceed ASHRAE 90.1 standards.
⁹    All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
¹⁰   Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.