Installation Instructions
HOOD EXHAUST
NOTE: 5HDGWKHVHQH[WWZRSDJHVRQO\LI\RXSODQWRYHQW\RXUH[KDXVWWRWKHRXWVLGH,I\RXSODQWRUHFLUFXODWHWKHDLU
EDFNLQWRWKHURRPSURFHHGWRSDJH6.%HORZDUHH[DPSOHVRI2XWVLGH7RS([KDXVWDQG2XWVLGH%DFN([KDXVWGXFWV\VWHP
OD\RXWV1RWHWKHSRVLWLRQRIWKHPLFURZDYHRYHQUHODWLYHWRWKHGXFWV\VWHP
2876,'(723(;+$867 (;$03/(21/<
 
 
EQUIVALENT  
NUMBER  
EQUIVALENT
DUCT PIECES 
 
LENGTH  x 
USED 
LENGTH
 
  
   
 
   
Roof Cap  
 
24 Ft.  x 
(1) 
24 Ft.
 
   
 
 
   
12 Ft. Straight Duct  
12 Ft.  x 
(1) 
12 Ft. 
  
  (6s Round)
 
   
 
 
   
Rectangular-to-Round  5 Ft. 
(1) 
5 Ft. 
  
  Transition 
Adaptor* 
Equivalent lengths of duct pieces are based on actual tests and  
reflect requirements for good venting performance with any vent hood.
 
 
 
 
 
 
7RWDO/HQJWK
 
)W
* IMPORTANT:  If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will 
have to be cut to fit, using the tin snips, in order to allow free movement of the damper.
The following chart describes an example of one possible 
ductwork installation.
The following chart describes an example of one possible 
ductwork installation.
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared  
at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
2876,'(%$&.(;+$867 (;$03/(21/<
 
 
EQUIVALENT  
NUMBER  
EQUIVALENT
DUCT PIECES 
      LENGTH*      x 
USED 
LENGTH
 
  
   
 
   
Wall Cap  
 
40 Ft.       x 
(1) 
40 Ft.
 
   
3 Ft. Straight Duct  
3 Ft. 
     x 
(1) 
3 Ft. 
  
  (3
1
ø
4
s x 10s Rectangular)
 
   
 
 
   
90° Elbow 
 
10 Ft.       x 
(2) 
20 Ft.
 
 
Equivalent lengths of duct pieces are based on actual tests and  
reflect requirements for good venting performance with any vent hood. 
 
 
 
 
 
 
 
7RWDO/HQJWK
 
)W