Viking RVCH330BK 安装指导

下载
页码 8
12
13
CAUTION: Secure vent hood. Make sure mounting
screws are secured into framing using additional
mounting screws and wall anchors, if necessary.
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE:
Housing wiring must be properly installed for
wiring to be correct when wiring unit.
7
5/16”
nut driver
BLACK
BLACK
WHITE
WHITE
GREEN
BARE OR GREEN
8
3
4
5
Attach with screws and lock washers provided.
Attach with screws.
Remove electrical box cover.
1
6
2
Flip hood over. Insert 6” of electrical wiring through 
the top of vent hood and secure using wiring restrain.
Refer to local codes.
Replace electrical box cover. Make connection to
breaker box.
1
1
2
9
10
Slide filter front over front lip. Push filter rear up, 
then slide back over rear lip.
2
1
11
3
Assemble brackets to mesh filters and insert 
charcoal filters.
2
1
2
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
Installation
(RVCH Classic Chimney Wall Hoods w/Recirculating Kit)
W A R N I N G
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING
• Use this unit only in the manner intended by
the manufacturer. If you have any questions,
contact the manufacturer.
• Before servicing or cleaning unit, switch
power off at service panel and lock service
panel to prevent power from being switched
on accidentally. When the service
disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.