Dacor DR30DHLPH 设计指南
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DR30D, DR30DH, DR30DI, DR30DIH
Distinctive 30” Wide
Dual Fuel Range
Document # PG05-006
Revised 01/30/13 Page 2/6
ranges equipped for installation in Canada:
■
Freestanding ranges used in Canada require
a factory installed 4-wire appliance cord and
NEMA 14-50P plug. Order model number
DR30D-C or DR30DH-C. The appliance cord is
66 inch (168 cm) long.
■
Do not modify the factory wiring. The plug is
designed to plug directly into a NEMA 14-50R
electrical receptacle installed by a licensed
electrician.
all other models:
The wiring needs to be long enough to allow the range to be pulled out for
The wiring needs to be long enough to allow the range to be pulled out for
service, while remaining connected (see following page).
The wiring connected to the range must:
The wiring connected to the range must:
■
Meet NEMA standards and have a minimum rating of 250 Volts @ 30
Amp.
■
Include a strain relief.
■
Be terminated by tinned leads, closed loop terminals or open ended
spade lugs with upturned ends.
■
Connect to a junction box or receptacle installed by a licensed
electrician.
Where local code permits, a 3 or 4 wire appliance cord may be used. It
must:
■
Be UL listed type SRD or SRDT.
■
Be equipped with a NEMA 14-50P 4-wire plug or, where local code
permits, a NEMA 10-50P 3-wire plug.
Electrical Specifications
Circuit required
Total Connected Load
240 Vac, 60 Hz., 30 Amp.*
5.7 kW (23.8 Amp.)
■
The ratings above are for reference only - refer to the range's product
data label for exact specifications.
■
The correct voltage, frequency and amperage must be supplied to
the appliance from a separate, grounded, circuit that is protected by a
properly sized circuit breaker or time delay fuse. If a time-delay fuse is
utilized, fuse both sides of the line (L1 and L2).
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The regulator inlet accommodates a 3/4” gas line. The range ships with a
1/2” to 3/4” adapter connected to the regulator.
gas and Electrical requirements
a
B
C
D
4 3/4”
(12.1 cm)
22 1/8”
(56.2 cm)
8 3/4”
(22.2 cm)
13 3/4”
(34.9 cm)
B
Gas
inlet
A
C
7/8” (2.2 cm) dia. electrical
connection hole in bottom*
D
Range electrical access,
cover removed
GAs AND ELEctRIcAL DImENsIoNs
gas Supply Pressure requirements*
gas Type
Manifold Pressure
Minimum gas Supply
Pressure
Natural gas
5” water column
6” water column
LP
10” water column
11” water column
* Maximum input gas supply pressure for all models is 1/2 psi
7/8" to 1 1/8" dia. access hole
NEmA 14-50R
REcEPtAcLE
ovERALL DImENsIoNs - moDEL DR30DI[H]
WItH ERv3015 RAIsED vENt
Stiffener
Cabinet face*
Countertop*
*
IMPOrTaNT: See Countertop/Cabinet Cutout Dimensions for required countertop cutout dimensions.
There are three possible configurations.
**
IMPOrTaNT: If 3 1/4 inch side panels are removed, cabinet face must be flush with back of control panel.
Back of
control
panel
ERV3015
raised vent
DR30DI[H] range
3/8” min. (1.0 cm)
space behind
raised vent
chassis to clear
stiffener
3/8” min. (1.0 cm)
flat countertop
overhang required
behind cutout
3 1/4 inch
side panel**
Countertop height:
35 7/16" (90.0 cm) min.
37 7/16” (95.1 cm) max.
28 11/16” (72.9 cm)