It is extremely important to clean the inlet air filters once a month (or more often if operated in dusty or dirty locations or 
conditions)  to properly maintain the operational  performance of the PTAC unit.  The two intake air filters (constructed of 
durable polypropylene) can be easily inserted into the cabinet front using the cabinet filter guides. Before cleaning the intake 
filters, turn the unit off by setting the mode switch to the OFF position. Filters should be cleaned as required. The following 
procedure is used to remove the intake filters:
1. Facing the unit, pull up on the filter handles located at the front top of the unit.
2. Pull each filter upward and remove.
3. Clean filters with vacuum or with running water. Reverse this procedure to reinstall the filters.
Note:  Accessory filter kits are available from your sales person. All filters are permanent and cleanable. Consult your  
       I&O Manual for other monthly cleaning instructions.
s
PAre
 f
ilTers
 
Helps keep dirt and lint out of the air and off the coil, 
thus increasing the unit's efficiency. Amana® brand 
filters are easy to remove, wash and replace.
FK10A
10-pack - A Series
FK10B
10-pack - B, C & D Series
FK10E
10-pack - E Series 
(requires 2 filters per 
change.)
r
ePlACemenT
 C
HArCoAl
 f
ilTer
 K
iT
Absorbs  airborne  odors  caused  by  cigarette,  pipe 
or cigar smoke and odors caused by mold, mildew, 
etc. Filters are made of polyester fibers coated with 
activated  charcoal  and  are  individually  wrapped. 
These filters are permanent and can be washed or 
cleaned. Call your Amana® brand PTAC sales person 
for details. 10 filters per pack.
CFK10A
10-pack - A Series (R-22)
CFK10B
10-pack - B, C & D Series (R-22)
m
onTHly
 m
AinTenAnCe
d
uCT
 K
iTs
 (mdK01e, edK02b, TdK02b, PTdK01e, ddK01e)
Three kits must be supplied to provide ducted, conditioned 
air into a second room: a main duct kit, an extension duct kit 
and a terminal duct kit.
H
ydroniC
 H
eAT
 K
iT
Is required for heating functions instead of electric resistance 
heaters. Unit must retain complete service access with the 
kit installed. Proper water or steam valves must be used.
C
ondensATe
 r
emovAl
 P
umP
 (H
eAT
 P
umPs
 
only
)
Must  be  installed  to  assist  in  removing  the  condensate 
developed by the heat pump operation and transfer it to the 
indoor  coil  to  dissipate  into  the  room,  adding  humidity  to 
the room.
C
irCuiT
 b
reAKer
 K
iT
Must  be  installed  in  sub-base  to  provide  overcurrent 
protection  for  proper  230/208V  amperage.  Can  also  be 
used as a physical disconnect where local codes permit for 
230/208 voltage.
H
Ard
 W
ire
 K
iT
Must  be  used  to  permanently  wire  chassis  for  hard  wire 
purposes. (For 265V units, Hard Wire Kit may be substituted 
with Sub-base Kit.)
T
HermosTATs
A  manufacturer-approved  manual,  auto  changeover 
or  programmable  traditionally  wired  thermostat  must  
be installed to provide full remote operation of the chassis.  
A Remote Escutcheon Kit must be used to indicate remote 
operation.
C
onTrACTor
'
s
 b
id
 s
HeeT
 (
ConT
.)