4
Installation Specifications
 WARNING
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information.
To prevent an electric shock hazard, the power supply 
must meet the specifications stated below. It is the 
owner’s responsibility to make sure that the electrical 
service meets electrical requirements and that the 
electrical outlet has been properly installed by a 
licensed electrician.
Electrical Power Supply Requirements
The range is supplied with a factory installed, 6 foot 
long, power cord with a three-prong grounding plug. 
It is connected to the chassis at the rear of the range. 
It must be connected to a dedicated, grounded three-
prong electrical outlet installed by a licensed electrician.
The electrical installation, including minimum supply 
wire size and grounding, must be done in accordance 
with National Electric Code ANSI/NFPA 70* and local 
codes and ordinances. A copy of this standard may be 
obtained from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be 
supplied to the electrical outlet according to the product 
data label located on the top of the kick plate under the 
door. Remove the door to view the data label (see  
page 9). See the Electrical Supply Requirements 
table below for reference.
Electrical Circuit 
Required
Total Connected Load
120 Vac 60Hz,  
15 Amp.
0.5 kW  
(4.0 Amp.)
Electrical Supply Requirements
IMPORTANT: The above information is for reference only. 
If the information above differs from the information on the 
product data label on the appliance, use the information on 
the label.
Gas Supply Requirements
Be certain that the range being installed is correct for 
the gas service being provided (natural gas or LP gas). 
Check your local building codes for the proper method 
of installation. In the absence of local codes, this 
appliance should be installed in accordance with the 
National Fuel Gas Code ANSI Z223.1/NFPA 54.
An external manual shut-off valve must be installed 
between the gas inlet and the range for the purpose of 
turning on or shutting off gas to the appliance.
The cooktop comes from the factory with the regulator 
installed. Use only the installed regulator. The inlet 
accommodates a 3/4” gas line. The range ships with a 
1/2” to 3/4” adapter connected to the regulator.
Gas 
Type
Manifold 
Pressure* 
(WC)
Min. Gas Supply 
Pressure (WC)
Max. Input 
Pressure
Natural
5”
6”
1/2 p.s.i.
LP
10”
11”
1/2 p.s.i.
Gas Supply Requirements
* The gas supply pressure for testing the regulator setting 
shall be at least 1 inch water column (249Pa) above the 
specified manifold pressure.
IMPORTANT: The information above is for reference only. 
If the above data does not agree with the product data 
label, use the data on the product data label on top of the 
kick plate below the door (remove the door according to the 
instructions on page 9 to view it).
The gas connection is located on the back of the unit as 
shown below.
12 1/2”
(318 mm)
to
14 5/8”
(371 mm)
2 5/8”
(67 mm)
Power cord
Gas 
connection