IMPORTANT: Observe all governing codes and ordinances. 
 
Cabinet opening dimensions that are shown must be used. 
Given dimensions provide minimum clearance with oven.
 
Recessed installation area must provide complete 
enclosure around the recessed portion of the oven.
 
Grounded electrical supply is required. See “Electrical 
Requirements” section.
 
Electrical supply junction box should be located 3"  
(7.6 cm) maximum below the support surface when the 
oven is installed in a wall cabinet. A 1" (2.5 cm) minimum 
diameter hole should have been drilled in the right rear or 
left rear corner of the support surface to pass the appliance 
cable through to the junction box.
NOTE: For undercounter installation, it is recommended 
that the junction box be located in the adjacent right or left 
cabinet. If you are installing the junction box on rear wall 
behind oven, it is recommended that the junction box be 
recessed and located in the upper center of the cabinet. 
 
Oven support surface must be solid, level, and flush with 
bottom of cabinet cutout.
Floor must be able to support a single oven weight of           
 
154 lbs (70 kg).
Floor must be able to support a double oven weight of         
 
288 lbs (131 kg).
 
 IMPORTANT: To avoid damage to your cabinets, check 
with your builder or cabinet supplier to make sure that 
the materials used will not discolor, delaminate, or sustain 
other damage. This oven has been designed in accordance 
with the requirements of UL and CSA International and 
complies with the maximum allowable wood cabinet 
temperatures of 194°F (90°C).
Location Requirements
Undercounter Installation (With Cooktop Installed Above):
Ovens approved for this type of installation have an approval 
label located on the top of the oven. Refer to Cutout Dimensions 
For Ovens Installed Under Cooktop (separate sheet).
Product Dimensions – Single Ovens
%
'
(
$
&
*
)
A.   28 
³⁄
4
" (72.8 cm) max. overall height
B.   28 
7
16
" (72.2 cm) max. recessed width
C.   26 
³⁄
4
" (67.9 cm) recessed height
D. 23 
1/4
" (59.1 cm) max. recessed depth
E. 30" (76.2 cm) overall width
F.   12" (30.5 cm) from back of control panel to start of strain relief
G. 48" (121.9 cm) flexible conduit length