Dimensions
Tolerances: ±1/16” (±1.6 mm), -0 unless otherwise stated
* 18” 1/4 on model DHW482 with exhaust cowling
IMPORTANT: The minimum installed distance from the 
hood to the cooking surface must be no less than 30 
inches. The minimum specified distance may be higher 
for the particular range or cooktop in use. Check the 
manufacturers specifications for the cooktop or range.
Planning the Location
 WARNING
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information.
 
■ Carefully check the location where the hood is to be 
installed. The hood should be placed for convenient 
access. Make certain that electrical power can be 
provided in the selected location.
 
■ The hood model selected must be as wide as the 
cooktop surface or wider.
 
■ All contact surfaces between the hood and any cabi-
nets or walls must be solid and at right angles.
 
■ Install the range hood and cooking appliance(s) so 
that they can be removed if service is required.
 
■ Plan the installation so that all minimum dimensions 
are met or exceeded. Dimensions shown above pro-
vide minimum clearances, unless otherwise noted.
Performance Specifications
All Models
Blower
600 CFM* (for single blower units)
1200 CFM* (for dual blower units) 
Blower Speeds 4 with electronic speed control
Lights
12 Vac, 20 Watt halogen
Filters
Baffle type, dishwasher safe
Exhaust
8-inch
Finish
430 stainless steel
Total Connected 
Load
120 Vac, 60 Hz.  
(See table below for current draw)
Circuit
Requirement
120 Vac, 15 Amp. grounded,  
dedicated circuit, minimum
* At zero inches static pressure
Model Specific
Model
Blowers Lights
Filters
Maximum 
Current 
Draw
DHW301
1
2
1
3.4 Amp.
DHW361
1
2
1
3.4 Amp.
DHW421
1
3
1
3.6 Amp.
DHW482
2
4
2
6.8 Amp.
Electrical Specifications
 WARNING
The electrical service to the range hood should be 
installed only by a licensed electrician.
It is the owner’s responsibility to ensure that the electrical 
connection of this appliance is performed by a qualified 
electrician. The electrical installation, including minimum 
supply wire size and grounding, must be in accordance 
with the National Electric code ANSI/NFPA* (or latest 
revision) and local codes and ordinances.
* A copy of this standard may be obtained from:
National Fire Protection Association  
1 Batterymarch Park 
Quincy, Massachusetts 02269-9101
Connect the hood to a junction box supplied by a 120 
Vac, 60 Hz. dedicated, grounded, 3-wire (hot, neutral, 
ground) circuit protected by a 15 Amp. circuit breaker or 
time delay fuse. Locate the junction box a minimum of 
17” (43.2 cm) above the bottom of the range hood (for 
example, attached to a stud).
Installation Specifications 
Chimney 
24”
(61.0 cm)
Min. 30 1/4” (76.8 cm) Max. 42” (106.7 cm)
30” - 36” - 42” - 48”
15”
(38.1 cm)
11 3/4”
(29.8 cm)
5 3/4”
(14.6 cm)
12 1/2” (31.8 cm)
16 1/4” * (41.3 cm)