Perlick HA24FB31L 使用和维护

下载
页码 12
perlick residential installation manual
10
perlick.com
TROUBLESHOOTING
If the unit appears to be malfunctioning, read through 
the OPERATION section of this manual first. If the problem 
persists, check this troubleshooting section to see if you 
can refer to the cause and remedy of the problem and 
resolve it without a service call. 
DANGER
Never attempt to repair or perform maintenance on 
the unit until the main electrical power to the unit has 
been disconnected!
Problem
Cause
Solution
No interior light
Bulb is loose 
•  Tighten bulb
Bulb is burnt out
•  Replace bulb
LED board is inoperable
•  Contact Perlick Technical Service at 
800-558-5592
Light stays on when door switch is closed
Manual switch is on
•  Turn manual switch off
Door is not making contact with the door 
switch
•  Makre sure the door closes tightly
Noisy operation
Soft sounds from compressor, fan motor and 
valves heard
•  Normal operation
“Crackling” sound during defrost
•  Normal operation
LED Controller display is flashing ”P1”*
Thermostat probe has failed
•  Contact Perlick Technical Service at 
800-558-5592
LED Controller display is flashing “P2”*
Evaporator probe has failed
•  Contact Perlick Technical Service at 
800-558-5592
LED Controller display is flashing “HA”*
Internal compartment has exceeded the high 
temperature alarm preset value for over 30 
minutes.
•  Make sure the door is completely closed.
•  Check the door gasket seal. Replace if 
necessary.
•  Check the condenser and clean it if 
necessary.
•  Make sure the louvered plate is 
unobstructed. If surrounding ambient 
temperature has recently changed 
dramatically, the compartment may be 
affected.
•  Make sure the interior light is off.
•  Warm product was recently placed in the 
cabinet. Wait 24 hours for the product to 
chill and then recheck the temperature.
LED Controller display is flashing “LA”*
Internal compartment has exceeded the low 
temperature alarm preset value for over 30 
minutes.
•  Make sure the door is completely closed.
•  Check the door gasket seal. Replace if 
necessary.
•  If the surrounding ambient temperature 
has recently changed dramatically, the 
compartment temperature  may be 
affected.
Unit is not running
No power is going to the unit.
•  Home circuit breaker was tripped. Reset 
the circuit breaker.
•  ON/OFF keypad is turned off. Turn it on.
•  If it is a Dual-Zone model, check the Dual-
Zone power switch (see page 4).
Condenser is dirty.
•  Clean the condenser
* Applies to Signature Series models only