Perlick HA24FB31L 安装指导

下载
页码 13
PERLICK RESIDENTIAL INSTALLATION MANUAL
4
perlick.com
SAFETY
PLEASE READ all instructions completely before attempting 
to install or operate the unit. Take particular note of the 
DANGER,  WARNING and CAUTION information in the 
manual. The information is important for the safe and 
efficient installation, operation and care of your Perlick unit.
DANGER
Indicates a hazard that WILL result in serious injury or 
death if precautions are not followed.
Indicates a hazard MAY cause serious injury or death if 
precautions are not followed.
WARNING
Indicates a hazard where minor injury or product 
damage may occur if precautions are not followed.
CAUTION
PRIOR TO INSTALLATION
Carefully inspect cabinet for hidden damage. If damage is 
discovered, file your claim immediately with the transport 
company. Perlick is not responsible for damage in transit.
When moving the unit, be sure 
to protect finished flooring with 
appropriate material to avoid damage from moving 
the unit.
Do not lift unit by drawer, shelving 
or door handles, as damage to the 
unit could occur if not moved as instructed.
To prevent personal injury, a 
minimum of two people are 
required to lift the unit. Larger units may require 
additional personnel.
Before moving the unit, secure the door shut with tape 
to prevent door from swinging open while being moved. 
Carefully move unit to installation site and place in front of 
opening.
If unit has been laid on its back or 
sides, place unit upright and allow 
minimum of 24 hours before connecting power.
CAUTION
CAUTION
WARNING
CAUTION
PLUMBING
No plumbing connections are required. Condensate from 
the cooling coil is automatically evaporated through a 
condensate pan located in the condensing section of the 
unit.
ELECTRICAL
A 115 volt, 60 Hz, 15 amp circuit breaker and electrical 
supply are required. A separate circuit is required for each 
Perlick unit installed.
Follow the National Electrical Code and any local codes or 
ordinances when installing the receptacle.
All Perlick units come equipped with a NEMA 5-15P 90° plug 
with a 5’ cord extending beyond the rear of the cabinet. 
The electrical outlet must be flush with, or recessed into, 
the wall surface for all HP, HC and HA models. HH models 
have a recess at the rear of the cabinet to accomodate the 
plug and keep a true 18” depth. 
Do not attempt to operate the 
equipment on any other power 
source than that listed on the Electrical Specification 
Plate attached to the unit.
Serious Electrocution Hazard! 
Electrical grounding is required. 
This appliance is equipped with a 3-prong (grounding) 
polarized plug for your protection against possible 
shock hazards. Failure to comply with these electrical 
guidelines may result in possible death or serious 
injury, fire, or loss of property.
•  Never remove the round grounding prong from the 
plug.
•  Never use a 2-prong adapter.
•  Never use extension cord to connect power to the unit.
•  If a 2-prong receptacle is encountered, or a longer power 
cord is required, contact a qualified electrician to have it 
replaced in accordance with applicable electrical codes. 
 
ADDITIONAL GENERAL INFORMATION
•  All electrical instructions assume the outlet is located 
4” - 10” above the floor surface.
•  Floor must be level in area of installation. Leg levelers 
are used for fine-tune adjustment only and should not 
be used to compensate for floor differences exceeding 
1/2”.
DANGER
CAUTION