ZIC30GNHII/ZIK30GNHII
GE Monogram
® 
30" Fully Integrated Customizable Refrigerators for  
Dual Installation
Dimensions and Installation Information (in inches) 
The Installation Space
The finished cutout width must be 30".
The cutout depth must be 25" for flush installations. 
•  The front face of the refrigerator fits flush with 25" depth 
adjacent cabinets.
Electrical 
A 115V, 60Hz., 15 or 20 amp power supply is required. An 
individual properly grounded branch circuit or circuit breaker 
is recommended. Install a properly grounded 3-prong 
electrical receptacle recessed into the back wall. Electrical 
must be located on rear wall as shown. 
Note: GFI (ground fault interrupter) is not recommended.
Height options
80” or  * 84“ 
25” min. depth
30” Finished Width
Height adjustable
from 79-3/8” to 80-3/8”  *
3/4”
23-3/4”
29-3/4”
1/8”
1-1/4”
4”
4”
3-1/8”
60" Finished Width
Wall
View
84"
max
80"
min
Finished
Opening
25"min. Cutout
Depth
77"
6"
Anti-tip location do not obstruct
Water Tube & Electrical Outlet
Water Line 
•  A cold water supply is required for automatic icemaker 
operation. The water pressure must be between 40 and 120 
p.s.i.
•  Route 1/4" OD copper or GE SmartConnect
 plastic 
tubing between the house cold water line and the water 
connection location.
•  Tubing should be long enough to extend to the front of the 
refrigerator. Allow enough tubing to accommodate a bend 
leading into the water line connection.
•  Water line can enter an opening through the floor or back wall. 
•  Install a shut-off valve between the icemaker water valve 
and cold water cupply in the home.
Note: When two units are placed side by side, 
order heater kit ZUG30.