Ice maker
 
Fault
Possible cause
Remedial action
The ice maker doesn’t work.
Ice maker is not connected 
to the mains supply.
Call customer service.
Ice maker does not contain any fresh 
water.
Ensure that the water is properly connected. 
The freezer compartment temperature 
is too warm.
Check freezer compartment temperature 
and, if required, set slightly colder.
The ice maker does not make 
enough ice or the ice is 
deformed.
The appliance or ice maker has only 
just been switched on.
Approx. 24 hours is needed until ice pro-
duction starts.
A lot of ice has been taken.
Approx. 24 hours is needed until the ice 
cube container is filled again.
Low water pressure.
Connect the appliance to the stipulated 
water pressure only (see chapter Connect-
ing appliance, section Water connection).
The water filter is bunged up or used. Change the water filter.
The ice maker does not make 
any ice.
The ice maker is switched off.
Switch the ice maker on at the control 
panel.
The appliance is not supplied with 
water.
Contact the installer or the water supply 
company.
Water supply has kinks.
Turn off the water supply at the shut-off tap. 
Smoothen out the kinks, exchange where 
necessary.
Low water pressure.
Connect the appliance to the stipulated 
water pressure only (see chapter Connect-
ing appliance, section Water connection).
Temperature in the freezer space is 
too warm.
Set temperature slightly colder in the freezer 
compartment.
Ice cube container is not properly 
inserted.
Check the position, re-insert where neces-
sary.
Incorrect shut-off tap installed.
Incorrect taps can cause low water pressure 
and damage to the appliance.
Ice forms in the inflow hose 
to the ice maker.
Low water pressure.
Connect the appliance to the stipulated 
water pressure only (see chapter Connect-
ing appliance, section Water connection).
Shut off tap incorrectly opened.
Open shut off tap fully.
Temperature in the freezer space is 
too warm.
Set temperature slightly colder in the freezer 
compartment.
Water runs from the appliance. The water connection hose is not 
properly sealed.
Replace the hose with a manufacturer’s 
original part.
Incorrect shut-off tap installed.
Incorrect taps can cause low water pressure 
and damage to the appliance.
The water pressure is less than 
usual.
Low water pressure.
Connect the appliance to the stipulated 
water pressure only (see chapter Connect-
ing appliance, section Water connection).
Shut off tap incorrectly opened.
Open shut off tap fully and check for leaks. 
Check the minimum through flow.
Incorrect shut-off tap installed.
Incorrect taps can cause low water pressure 
and damage to the appliance.
Water supply has kinks.
Turn off the water supply at the shut-off tap. 
Smoothen out the kinks, exchange where 
necessary.
The water filter is bunged up or used. Change the water filter.