Monogram ZSA1202RSS 规格说明表单
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
®
service, 800.626.2000.
140022
Specification Revised 3/11
Listed by
Underwriters
Laboratories
ZSA1201RSS/ZSA1202RSS
GE Monogram
®
120 Above-the-Cooktop Advantium
®
Oven
Dimensions and Installation Information (in inches)
Hood Exhaust Duct
Outside ventilation requires a hOOd ExhAuST duCT.
Read the following carefully.
Read the following carefully.
EXHaUSt CoNNECtIoN:
The hood exhaust has been designed to mate with a
standard 3-1/4” x 10” rectangular duct.
The hood exhaust has been designed to mate with a
standard 3-1/4” x 10” rectangular duct.
if a round duct is required, a rectangular-to-round
transition adaptor must be used. do not use less than a
6” diameter duct.
transition adaptor must be used. do not use less than a
6” diameter duct.
REaR EXHaUSt:
if a rear or horizontal exhaust is to be used, care should
be taken to align exhaust with the space between studs,
or wall should be prepared at the time it is constructed
by leaving enough space between the wall studs to
accommodate exhaust.
if a rear or horizontal exhaust is to be used, care should
be taken to align exhaust with the space between studs,
or wall should be prepared at the time it is constructed
by leaving enough space between the wall studs to
accommodate exhaust.
Grille
Filter Kit accessory
Filter Kit
Jx81d–Recirculating
Charcoal Filter kit
To be used when
the Advantium oven
cannot be vented
to the outside.
Jx81d–Recirculating
Charcoal Filter kit
To be used when
the Advantium oven
cannot be vented
to the outside.
maXImUm DUCt LENGtH:
For satisfactory air movement, the total duct length of
3-1/4” x 10” rectangular or 6” diameter round duct should
not exceed 140 equivalent feet.
For satisfactory air movement, the total duct length of
3-1/4” x 10” rectangular or 6” diameter round duct should
not exceed 140 equivalent feet.
ELBoWS, tRaNSItIoNS, WaLL aND RooF CapS, etc.,
present additional resistance to airflow and are equivalent
to a section of straight duct which is longer than their
actual physical size. when calculating the total duct
length, add the equivalent length of all transitions and
adaptors plus the length of all straight duct sections. The
chart below shows the approximate feet of equivalent
length of some typical ducts.
present additional resistance to airflow and are equivalent
to a section of straight duct which is longer than their
actual physical size. when calculating the total duct
length, add the equivalent length of all transitions and
adaptors plus the length of all straight duct sections. The
chart below shows the approximate feet of equivalent
length of some typical ducts.
Duct
Equivalent
a. Rectangular-To-Round
5 Ft.
Transition Adaptor
B. wall Cap
B. wall Cap
40 Ft.
C. 90° Round Elbow
10 Ft.
D. 45° Round Elbow
5 Ft.
E. 90° Rectangular Elbow
25 Ft.
F. 45° Rectangular Elbow
5 Ft.
G. Roof Cap
24 Ft.