Dacor DR30DLP 安装指导
10
Electrical Connection (Continued)
Connecting the Conduit to the House
Electrical Junction Box
WARNING
Do not ground the appliance to a gas supply pipe or hot
•
water pipe.
Do not turn on power to the appliance without it being
Do not turn on power to the appliance without it being
•
permanently grounded.
A grounded cold water pipe must have metal continuity to
A grounded cold water pipe must have metal continuity to
•
electrical ground and must not be interrupted by insulating
materials. Any insulating materials must be jumpered with a
length of No. 4 copper wire securely clamped to bare metal
at both ends.
NOTES:
The power supply must be properly polarized. Reverse
•
polarity will result in continuous sparking of the electrodes,
even after flame ignition.
If there is any doubt as to whether the power supply is
If there is any doubt as to whether the power supply is
•
properly polarized or grounded, have it checked by a licensed
electrician.
With the range positioned directly in front of the cabinet
With the range positioned directly in front of the cabinet
1.
cutout, feed the appliance wires into the junction box.
Depending upon local codes, utilize one of the three (3)
methods shown to connect the appliance to the junction box.
Connect the white wire from the appliance to the neutral
Connect the white wire from the appliance to the neutral
2.
(white) supply wire in the junction box.
Connect the black wire from the appliance to the black (L1)
Connect the black wire from the appliance to the black (L1)
3.
power supply wire in the junction box.
Connect the red wire from the appliance to the red (L2) power
Connect the red wire from the appliance to the red (L2) power
4.
supply wire in the junction box.
If using a 4-wire connection, connect the green wire to a
If using a 4-wire connection, connect the green wire to a
5.
grounded supply wire in the junction box or to a grounded
cold water pipe. If connecting to a grounded cold water pipe:
Use a separate copper grounding wire (No. 10 minimum)
◊
to connect to the cold water pipe by means of a clamp
and an external grounding connector screw.
If there are any materials that isolate the cold water pipe
If there are any materials that isolate the cold water pipe
◊
from ground, jumper it with a No. 4 copper wire, clamped
on both ends.
Replace the junction box cover.
6.
Installation Instructions
RED
RED
RED
GREEN
WHITE
WHITE
WHITE
BLACK
BLACK
BLACK
GREEN
Connection to
power supply
Wire nut
4 places
Junction box
4-Wire Connection Conduit
Junction Box Connection
Connection to appliance
(page 9)
Connection to
power supply
Wire nut
3 places
Junction box
3-Wire Connection Conduit
Junction Box Connection
Connection to appliance
(page 9)