Dacor ER36GISCHNG 设计指南
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.10
CL
CL
12 1/2” (318 mm)
15” (381 mm)
12” (305mm)
2 1/2”
(64mm)
3 1/2”
(89mm)
1” (25mm)
36” Wide, Epicure
®
Gas Range
ER36G, ER36GI
15 7/8”
(403 mm)
to
18”
(457 mm)
3 3/4”
(95 mm)
Back of Range
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural
5”
6”
1/2 p.s.i.
LP
10”
11”
1/2 p.s.i.
Document # PG05-002
Revised 05/07/09 Page 3/3
IMPORTANT: The information above is for reference only. If the
above data does not agree with the product data label, use the
data on the product data label on top of the kick plate below the
door (remove the door according to the installation instructions to
view it).
The gas connection is located on the back of the unit as shown.
The gas connection is located on the back of the unit as shown.
Use a 1/2" male NPT to connect to the regulator.
Utility Clearance Behind Range