Controls 
Use  the  high  suction  speed  in  cases  of  concentrated  kitchen  vapours.    It  is  recommended  that  the  cooker  hood  suction  is 
switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately 
after terminating cooking.  
Note:  Hood retains last speed setting when aspiration switch is turned off. 
 
Description of control panel 
  
 
1. Light Button 
•  Press lamp button to turn ON the light on High Intensity (Lamp state previously OFF). 
•  Press lamp button to turn ON the light on Low Intensity (Lamp state previously ON). 
•  Press lamp button to turn OFF the light (Lamp state previously ON). 
2. Timer Button 
•  The default timer setting is 10 minutes, and it can be adjusted between 60 minutes and 1 minute. 
•  After pressing the timer button, the control enters to a timer setup mode, and user can adjust the timer countdown time 
with the “+” and “-” buttons within 5 seconds. The timer can be initiated immediately pressing the timer button, after 
setting the timer duration or pressing the timer button twice (default 10 minutes setting). 
•  If no action occurs within 5 seconds, the countdown will start. 
•  During the timer setup the “+” and “-” buttons are dedicated to the timer and no motor action will occur. 
•  Once the timer is initiated, it can be cancelled by pressing the timer button again. 
3. Display 
•  Shows the hood settings. 
4. “-” Button. Speed Decrease / OFF 
•  This button is used to decrease the fan speed, or turn OFF the fan. 
•  The fan will turn OFF if the “-” button is pressed and the hood was in the first speed. 
•  If the fan is at second speed and the “-” button is pressed, the fan will be set to first speed. 
•  If the fan is at third speed and the “-” key is pressed, the fan will be set to second speed. 
•  If the fan is at fourth speed and the “-” button is pressed, the fan will be set to third speed. 
•  If the fan is OFF and the “-” button is pressed, the control backlight will light up. 
5. “+” Button. Speed Increase / ON 
•  This button is used to increase the fan speed, or turn ON the fan. 
•  The fan will turn ON if the “+” button is pressed and the hood was OFF. 
•  If the fan is at first speed and the “+” button is pressed, the fan will be set to second speed. 
•  If the fan is at second speed and the “+” button is pressed, the fan will be set to third speed. 
•  If the fan is at third speed and the “+” button is pressed, the fan will be set to fourth speed. 
•  If the fan is at fourth speed and the “+” button is pressed, a beep will sound. 
Clock programming 
•   The clock can be reprogrammed at any time except during an active timed function. 
•   The clock can be displayed in a twelve hour format and valid clock times are from 1:00 to 12:59. 
•   The clock can be reprogrammed pressing the “Timer” button for 3 seconds, and after, the clock can be adjusted with the “+” 
and “-” buttons. Colon “:” will flash indicating clock programming mode. 
•   The user can have minute increments / decrements of 1 minute, but if the user keep pressing the “+” / ”-” buttons for more 
than 1 second, the increments / decrements will be of 5 minutes.  
 
During this option the control will round to the nearest 5 minutes. 
•   The user can finish on reprogramming the clock pressing the “Timer” button. 
•   After 1 minute of no button pressed the control will accept the programmed clock time and will add one minute to the set 
clock. 
Grease filter saturation alarm (Optional) 
•   After thirty fan functional hours, the display will show “Grease Filter” if the fan is active.  
 
When this icon is shown in the display, the grease filters installed are required to be washed. 
•   To reset the grease filter saturation alarm the user must press the “+” button for 5 seconds, after this action the icon “Grease 