GE GTD65GBSJWS 规格指南

下载
页码 4
GTD65GBSJ 
GE
®
 Series 7.4 cu. ft. capacity Aluminized alloy drum gas dryer with HE Sensor Dry
Specification Created 7/15
For answers to your Monogram,
® 
GE Profile
 
or GE
®
 appliance questions, visit our website 
at geappliances.com or call GE Answer Center
®
 
service, 800.626.2000.
EXHAUST OPTION: When viewed from the front 
of the unit, exhaust 3-way via rear, left and bottom. 
Dryer is shipped exhausted to the rear. Alternate 
exhausting knockouts are supplied.
GAS:  An individual, properly-grounded branch circuit, 
with a three-prong grounding-type receptacle, protected 
by a 15 or 20 amp circuit breaker or a time-delay fuse is 
required.
GAS DRYER ELECTRIC RATING: 120V, 60Hz, 6A
GAS (BTU/HR): 22,000. Factory-equipped for 
natural gas. Tested for LP gas. LP gas supply requires 
a conversion kit. Check installation instructions for 
correct kit and have a qualified gas technician install a 
conversion kit. See dryer ducting information for proper 
installation.
NOTE: Dryer wall outlet must be located within 36" of 
service cord entry and accessible when dryer is mounted 
in position.
INSTALLATION INFORMATION: For complete 
information, see installation instructions packed with 
your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION: 
-  If your dryer is approved for installation in an alcove or closet, it will be stated on a 
label  on the dryer back.
The dryer MUST be exhausted to the outside.
-  Minimum clearances between dryer cabinet and adjacent walls or other surfaces 
are: 0" either side; 3" front and rear
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
-  Closet doors must be louvered or otherwise ventilated and must contain a 
minimum of 60 sq. in. of open area equally distributed. If this closet contains 
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of 
open area equally distributed.
-  No other fuel-burning appliance shall be installed in the same closet with a 
gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
The dryer MUST be exhausted to the outdoors. 
-  The installation must conform with the local codes, or in the absence of local 
codes, with the National Electric Code and National Fuel Gas Code, ANSI 
Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET 
INSTALLATION:
Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DRYER EXHAUSTING INFORMATION : 
Use metal duct only, vertical and horizontal ducting.