4-40 Banta Place Fair Lawn, NJ  07410  1-877-RCHOODS
 Transition of the duct to the outside should be designed according to the particular construction 
situation.  Some examples include the following.  A wall transition should be covered with a “dryer 
vent.” A sloped roof transition requires a cover like a duct with a sloped hat.   A flat roof transition 
needs a goose neck shape that blows the fumes directly onto the roof.
 No matter what transition the fumes have to pass through before they are released into the atmosphere, 
they MUST always pass a back draft damper. This  prevents the cold winter air from entering the 
kitchen through the ventilation ducts when the hood fan is not running.  Units with lighter smaller 
louvers work better than those with a large closure.