Carrier CA36K326 业主指南

下载
页码 36
A NOTE ABOUT SAFETY
Any time you see this symbol
in manuals, instructions and on
the unit, be aware of the potential for personal injury. There are
three levels of precaution:
DANGER identifies the most serious hazards which will result in
severe personal injury or death.
WARNING signifies hazards that could result in personal injury or
death.
CAUTION is used to identify unsafe practices which could result
in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in
enhanced installation, reliability, or operation.
PERSONAL INJURY, DEATH AND / OR PROPERTY
DAMAGE HAZARD
Failure to follow this warning could result in personal injury,
death or property damage.
Improper
installation,
adjustment,
alteration,
service,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions which may cause personal injury or
property damage. Consult a qualified installer, service agency,
or your distributor or branch for information or assistance. The
qualified
installer
or
service
agency
must
use
factory--authorized kits or accessories when modifying this
product.
Read and follow all instructions and warnings, including labels
shipped with or attached to unit before operating your new air
conditioner.
!
WARNING


































GENERAL
The high wall fan coil unit provides quiet, maximum comfort. In
addition to cooling and/.
IMPORTANT: The high wall fan coil unit should be installed by
authorized personnel only; using approved tubing and accessories.
If technical assistance, service or repair is needed, contact the
installer.
The high wall fan coil unit can be set up and operated from the
remote control (provided). If the remote is misplaced, the system
can be operated from the “Auto” setting on the unit.
Operating Mo
five operating modes.
S
Fan only
S
Auto
S
Heating (heat pump models only)
S
Cooling
S
Dehumidification (DRY)
Fan Only
In Fan Only mode, the system filters and circulates room air
without changing room air temperature.
Auto
In Auto mode, the system will automatically cool or heat the room
according to the user--selected set point.
Heating
In Heating mode, the system heats and filters room air.
Cooling
In Cooling mode, the system cools, dries and filters room air.
Dehumidification (DRY)
In Dehumidification mode, the system dries, filters and slightly
cools room air temperature.
This mode prioritizes air
dehumidification but it does not take the place of a dehumidifier.
Remote Control
The remote control transmits commands to set up and operate the
system. The control has a window display panel that shows the
current system status. The control can be secured to a surface
when used with the mounting bracket provided.
Model number Nomenclature
Model Numbers
The first two digits indicate the equipment type.
40 = Indoor unit; 
38 = Outdoor uni
Digit 5 indicates the system's type:
C = Cooling only;
Q = Heat pump
Maximum Number of fan coil units connected to the outdoor unit
B = 1:1
Digits 7, 8 indicate the system's capacity in 1000 
BTU/Hr
Example: 09 = 9000 BTU/Hr
Digit 9 - Indoor Fan Coil Unit Type
B = High-Wall
C = Cassette
D = Ducted
F = Console
G = Underceiling
H = High Wall Color Variation
- = Outdoor
Digit 12 indicates voltage
1 = 115/l/60
3 = 208-230-1-60Hz
40
MA 
Q
09
-- 
3
Digits 10, 11  - blank
Digits 3 and 4 represent the model
Unit Tons  Unit Btuh
0.75
9,000
12,000
18,000
208/230-1
40MBQB09D--3
40MBQB12D--3
40MBQB18D--3
208/230-1
208/230-1
1
1.5
24,000
40MBQB24D--3
208/230-1
2
36,000
40MBQB36D--3
208/230-1
3
48,000
40MBQB48D--3
208/230-1
4
Indoor Model
Number
Volt- Ph @
60Hz
2