GE GTH17JBX-BLK 用户指南

下载
页码 64
CONNECT THE TUBING TO THE
REFRIGERATOR 
(CONT.)
Fasten the tubing into the clamp provided to 
hold it in a vertical position. You may need to 
pry open the clamp.
7
Installation Instructions
10
CONNECT THE TUBING TO THE
REFRIGERATOR
NOTES:
• Before making the connection to the refrigerator,
be sure the refrigerator power cord is not plugged
into the wall outlet.
• We recommend installing a water filter if your
water supply has sand or particles that could clog 
the screen of the refrigerator’s water valve. Install 
it in the water line near the refrigerator. If using 
GE SmartConnect
Refrigerator Tubing kit, 
you will need an additional tube (WX08X10002) 
to connect the filter. Do not cut plastic tube to 
install filter.
Remove the access cover.
Remove the plastic flexible cap from the water 
valve (refrigerator connection).
Place the compression nut and ferrule (sleeve) 
onto the end of the tubing as shown. On GE
SmartConnect
Refrigerator Tubing kit, 
the nuts are already assembled to the tubing.
Insert the end of the tubing into the water valve
connection as far as possible. While holding the
tubing, tighten the fitting.
For plastic tubing from a GE SmartConnect
Refrigerator Tubing kit, insert the molded end 
of the tubing into the shutoff valve and tighten
compression nut until it is hand tight, then 
tighten one additional turn with a wrench.
Overtightening may cause leaks.
7
TURN THE WATER 
ON AT THE 
SHUTOFF VALVE
Tighten any connections 
that leak.
8
Tubing Clamp
1/4
″ Compression 
Nut
Ferrule 
(sleeve)
SmartConnect
Tubing
Refrigerator 
Connection
1/4
″ Copper
Tubing
PLUG IN THE REFRIGERATOR
Arrange the coil of tubing so that it does not vibrate
against the back of the refrigerator or against the wall.
Push the refrigerator back to the wall.
9
Move the feeler arm to the ON (down) position. The
icemaker will not begin to operate until it reaches 
its operating temperature of 15°F (–9°C) or below. 
It will then begin operation automatically.
START THE ICEMAKER
Feeler Arm in the
STOP (up) position
Feeler Arm in
the ON (down) position
10
NOTE:
In lower water pressure conditions, the
water valve may turn on up to 3 times to deliver
enough water to the icemaker.
Reattach the access cover.
INSTALLING THE WATER LINE 
(CONT.)
1