Electrical Connection - U.S.A. Only
Power Supply Cord
Direct Wire
1. Disconnect power.
2. Use Phillips screwdriver to remove the terminal block cover 
screw located on the back of the range. Pull cover down and 
toward you to remove cover.
3. Remove plastic tag holding three 10-32 hex nuts from the 
middle post of the terminal block.
4. Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
Feed the power supply cord through the strain relief in the 
cord/conduit plate on bottom of range. Allow enough slack 
to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
A. UL listed strain relief
A