Whirlpool W10413645A 产品数据表
Water Filtration System
Replacement Cartridge P6RFWB2 for System Models P6WB2L and P6WB2NL Capacity 200 Gallons (757.1 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Required Influent Challenge
Concentration
Maximum
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulates Class I
*
50% reduction
85% reduction
2.0 mg/L
7,300,00 #/mL
2.0mg/L ± 10%
At least 10,000 particles/mL
0.11 mg/L
75,000 #/mL
**
94.2
98.8
97
99.4
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Required Influent Challenge
Concentration
Maximum
Effluent
Minimum %
Reduction
Average
Reduction
Live Cysts
†
99.95%
160,000/L
≥50,000/L min.
54/L
†
99.97
99.99
Asbestos
99%
87 MFL
10
7
to 10
8
fiberls/L
††
ND (0.17) MFL >99
>99
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010 mg/L
0.010 mg/L
0.160 mg/L
0.140 mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
9 μg/L
6 μg/L
94.1
96.2
98.5
98.7
Lindane
0.0002 mg/L
0.0019 mg/L
0.002 mg/L ± 10%
0.1 μg/L
95.1
98.1
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 mg/L ± 10%
<1 μg/L
92.3
>93.2
Atrazine
0.003 mg/L
0.0094 mg/L
0.009 mg/L ± 10%
3 μg/L
68.9
84.1
2,4-D
0.07 mg/L
0.220 mg/L
0.210 mg/L ± 10%
16 μg/L
93.1
97.8
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.43 gpm (1.64 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68⁰F to 71.6⁰F (20⁰C to 22⁰C). Rated service capacity = 200 gallons (757 liters)
*Class I particulate size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust
†Based on the use of Cryptosporidium parvum oocysts
††Fibers greater than 10 um in length
®NSF is a registered trademark of NSF International
System tested and certified by NSF International against NSF/ANSI
Standard 42
Standard 42
for the reduction of Chlorine Taste and Odor, and
Particulate Class I*, and against NSF/ANSI Standard 53 for the
reduction of Live Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine,
and 2, 4-D.
reduction of Live Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine,
and 2, 4-D.