Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
VENTING REQUIREMENTS
E
xhaust venting: Exhaust your dryer to the outside. 4" (102 mm) 
diameter vent is required. Rigid or flexible metal exhaust vent 
must be used. Do not use plastic or metal foil vet. Exhaust hood 
must be at least 12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
Determine vent length and elbows needed for best 
drying performance:
 
Use following Vent System Chart to determine type of vent 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified  
in Vent System Chart. Exhaust systems longer than those 
specified will:
 
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
and increased energy usage.
Louvered Hood
Angled Hood
Box Hood
Exhaust hoods:
Recommended Styles:
Acceptable Style:
Determine vent path:
 
Select route that will provide straightest and most direct  
path outdoors.
 
Plan installation to use fewest number of elbows and turns.
 
When using elbows or making turns, allow as much room  
as possible.
 
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.
Vent System Chart
Number of 
90° turns or 
elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations for 27" wide 
models have a 90º turn inside the dryer. To determine 
maximum exhaust length, add one 90º turn to the chart.
Vent System Chart
(29" Wide Long Vent Models Only)
Number of 
90° turns  
or elbows
Type  
of vent
Box/louvered, or  
Angled hoods
1
4
3
2
0
Rigid metal
120 ft. (36.6 m)
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.4 m)
80 ft. (24.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
5
70 ft. (21.3 m)
Rigid metal
The “Vent System Chart” provides venting requirements that will 
help achieve best drying performance.