Whirlpool WEE760H0DH 安装指导
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
Check that all parts are included.
■
3 - 10-32 hex nuts (attached to terminal block)
■
3 - Direct wire lugs
■
2 - #10 x 1
⁵⁄₈" (4.1 cm) screws (for mounting anti-tip bracket)
■
Anti-tip bracket (inside oven cavity)
Anti-tip bracket must be securely mounted to the back wall or
floor. Thickness of flooring may require longer screws to
anchor bracket to subfloor. Longer screws are available from
your local hardware store.
floor. Thickness of flooring may require longer screws to
anchor bracket to subfloor. Longer screws are available from
your local hardware store.
■
For model:
Parts needed
If using a power supply cord kit:
■
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1
³⁄₈" (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
or open-end spade terminals with upturned ends.
■
A UL listed strain relief.
Check local codes. Check existing electrical supply. See the
appropriate “Electrical Requirements” section.
appropriate “Electrical Requirements” section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
licensed, qualified electrical installer.
Optional Parts
To purchase these or any other accessories, please reference the
“Accessories” section of the User Guide for contact information.
“Accessories” section of the User Guide for contact information.
■
Side Trim Kits:
White - Order Part Number W10677527
Black - Order Part Number W10675026
Stainless Steel - Order Part Number W10675028
White - Order Part Number W10677527
Black - Order Part Number W10675026
Stainless Steel - Order Part Number W10675028
■
Backsplash Kits:
High 6" (15.2 cm) White - Order Part Number W10655448
High 6" (15.2 cm) Black - Order Part Number W10655449
High 6" (15.2 cm) Stainless Steel - Order Part Number
W10655450
High 6" (15.2 cm) White - Order Part Number W10655448
High 6" (15.2 cm) Black - Order Part Number W10655449
High 6" (15.2 cm) Stainless Steel - Order Part Number
W10655450
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located behind the oven door on
the top right-hand side of the oven frame.
clearances specified on the model/serial rating plate. The
model/serial rating plate is located behind the oven door on
the top right-hand side of the oven frame.
■
The range should be located for convenient use in the
kitchen.
kitchen.
■
Recessed installations must provide complete enclosure of
the sides and rear of the range.
the sides and rear of the range.
■
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
or microwave hood combination that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
or microwave hood combination that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
■
All openings in the wall or floor where range is to be installed
must be sealed.
must be sealed.
■
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
Given dimensions are minimum clearances.
■
The anti-tip bracket must be installed. To install the anti-tip
bracket shipped with the range, see “Install Anti-Tip Bracket”
section.
bracket shipped with the range, see “Install Anti-Tip Bracket”
section.
■
Grounded electrical supply is required. See the appropriate
“Electrical Requirements” section.
“Electrical Requirements” section.
■
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
floor covering can withstand at least 200°F (93°C).
■
Use an insulated pad or ¼" (0.64 cm) plywood under range if
installing range over carpeting.
installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
■
Tape measure
■
Flat-blade screwdriver
■
Phillips screwdriver
■
Level
■
Hand or electric drill
■
Wrench or pliers
■
Marker or pencil
■
Masking tape
■
¼" (13 mm) drive ratchet
■
¼" (13 mm) nut driver
■
³⁄₈" (10 mm) and ⁵⁄₁₆" (8 mm)
nut driver
nut driver
■
¹⁄₈" (3 mm) drill bit (for wood
floors)
floors)
■
Tin snips or large wire
cutters (for cutting ground
strap if necessary)
cutters (for cutting ground
strap if necessary)
WEC530H0D
WEE730H0D
YWEE730H0D
WEE730H0D
YWEE730H0D
JES1450CD
JES1450D
JIS1450CD
JIS1450D
KSEG700E
KSEB900E
KSIB900E
MES8880D
WEE760H0D
YKSEG700E
YKSEB900E
YKSIB900E
YMES8880D
YWEE760H0D
JES1450D
JIS1450CD
JIS1450D
KSEG700E
KSEB900E
KSIB900E
MES8880D
WEE760H0D
YKSEG700E
YKSEB900E
YKSIB900E
YMES8880D
YWEE760H0D
Oven racks
2
3