Frigidaire FFES3015LS 安装指导

下载
页码 24
6
30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
Canada Style
Figure 1
2.
 Power Supply Cord Kit (U.S.A.)
The user is responsible for connecting the power supply 
cord to the connection block located behind the back 
panel access cover.
This appliance may be connected by means of 
permanent "hard wiring"; flexible armored or 
nonmetallic shielded copper cable (when local code 
allow it) or by means of a power supply cord kit.
NOTE: Electric Slide-in Range is shipped from factory 
with 1 1/8" (2.9 cm) dia. hole as shown on figure 3. If a 
larger hole is required, punch out the knockout.
 Risk of fire or electrical shock 
exists if an incorrect size range cord kit is used, the 
Installation Instructions are not followed, or the 
strain relief bracket is discarded.
For mobile homes, new installations or recreational 
vehicles, use only a power supply kit designed for a 
range at 125V/250V 50A recommended (minimum 
40A). Cord must have either 3 (when local code permits 
grounding through neutral) or 4 conductors. Terminal on 
end of wires must be either closed loop or open spade 
lug with upturned ends. Cord must have strain-relief 
clamp.
 Do not loosen the nuts which 
secure the factory-installed range wiring to 
terminal block while connecting range. Electrical 
failure or loss of electrical connection may occur.
3.
 Access to Terminal Block & 
Grounding Strap (U.S.A.)
Electrical Shock Hazard
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring system, 
or a grounding connector should be connected 
to the grounding terminal or wire lead on the 
appliance.
Failure to do any of the above could result in a 
fire, personal injury or electrical shock.
1.
 Factory Connected Power Supply 
Cord (Canada only)
This range is equipped with a factory-connected power 
cord (see Figure 1). Cord must be connected to a 
grounded 120/240 volt or 120/208 volt range outlet. If 
no outlet is available, have one installed by a qualified 
electrician.
BEND REAR WIRE COVER HERE
FOR ACCESS TO TERMINAL BLOCK
Figure 2
 This appliance is manufactured 
with the frame grounded by connection of a 
grounding strap between the neutral power 
supply terminal and the frame. If used in USA, 
in a new branch circuit installation (1996 NEC), 
mobile home or recreational vehicle, where local 
code do not permit grounding through neutral 
(white) wire or in Canada; remove the grounding 
strap from the frame and cut the other end, near 
the neutral terminal. Connect the appliance in 
usual manner.
Serial Plate Location
You will find the model and serial 
number printed on the serial 
plate. The serial plate is located as 
shown.
Remember to record the serial 
number for future reference.