Oasis R1P - Remote Water Chiller 规格说明表单

下载
页码 2
REMOTE WATER CHILLERS
 
R1P
Suggested Specification
Remote drinking water chiller shall deliver at least 1.0 gph of 
water at 50° F cooled from 80° F inlet water at 90° F ambient. 
Evaporator shall be copper evaporator tube on stainless steel 
water storage tank and both shall be encapsulated in insulation. 
Total water system shall be stainless steel. R-134a refrigerant 
system shall be hermetically sealed and refrigerant flow shall be 
capillary tube controlled. An adjustable thermostat having an off 
position shall control refrigeration system. Potable water system 
components shall comply with Safe Drinking Water Act Amend-
ments, the 1988 Lead Contamination Control Act and shall be 
Certified to ANSI 61 Section 9. Cooler shall be Listed by 
Underwriters Laboratories Inc. to U.S. and Canadian safety 
standards. Drinking water chiller shall be Oasis model R1P. 
Standard Features
> Powder coated galvanized steel cabinet with plastic front
> Air-cooled; designed to fit under a sink
> Compact, economical and easily installed
> Four foot (4’) insulated power cord with NEMA 5-15 plug
> Stainless steel storage tank
> 1/4” OD stainless steel water tube connections
> Welded water lines to eliminate corrosion and 
   assure leakproof operation
> HFC Refrigerant R-134a
> Product Certified to NSF/ANSI Standard 61, 
   Annex G (AB1953)
 
 
 
Components in these water coolers are lead free as
 
defined by the Safe Water Act Amendments of 1986,
 
and the Lead Contamination Control Act of 1988.
Limited 1-Year Warranty (Continental limits of the United 
States and Canada):  One year from the date of installation. 
Detailed warranty certificate enclosed with each drinking 
fountain; sample copy available upon request.
Export Warranty: One year on component parts. Detailed 
warranty certificate enclosed with each drinking fountain; 
sample copy available upon request.
Product Certified to NSF/ANSI Standard 61, Annex G 
(weighted average lead content of <=0.25%) and is in compli-
ance with California's Health & Safety Code Section 116875 
(commonly known as AB1953).
Model covered by this specification complies with all 
known Plumbing Codes. Listed by Underwriters’ Laboratories 
to U.S. and Canadian standards and conform to European 
Union Directives.
**
Specifications subject to change without notice
Model
Cooling Capacity
GPH
50° F Drinking Water
90° F Ambient Air Temp*
Base Rate
GPH
Pre-Cooler
Compr.
HP
Full Load 
Amps
Rated
Watts
115 Volts, 60 HZ
Glass Filler
Acc. Option
Cabinet
Color Finish
Net Wt. 
Approx.
R1P
 1
n/a  n/a
n/a  1/20 1.3 135 n/a  
White/gray
 30 
Lbs.
Hot ’N Cold™
Model
*Industry Standard Rating Condition 80° F inlet water temperature.