Page 12 
Conversion Back to Natural Gas 
If it is necessary to return the cooktop to natural gas service, repeat all of the steps in this procedure using the 
parts that have been removed. Use the chart below to determine the orifice sizes, shutter gaps, and the air 
shutter part numbers. 
 
Natural Gas Conversion Specifications 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Burner 
Location 
Bypass Orifice 
(X 100 mm) 
Main Orifice 
(X 100 mm) 
Air Shutter  
Part No. 
Air Shutter 
Gap 
Left Rear 
81 
184 
HN A-0053-E 
.38/9.6 
Left Front 
72 
135 
HN A-0052-E 
.09/2.3 
Right Rear 
72 
135 
HN A-0052-E 
.09/2.3 
Right Front 
81 
184 
HN A-0053-E 
.39/9.9 
Center Rear 
81 
194 
HN A-0053-E 
.37/9.5 
Center Front 
81 
194 
HN A-0053-E 
.38/9.7 
Model E48GC76EPS (48-Inch) 
Burner 
Location 
Bypass Orifice 
(X 100 mm) 
Main Orifice 
(X 100 mm) 
Air Shutter  
Part No. 
Air Shutter 
Gap 
Left Rear 
81 
184 
HN A-0053-E 
.37/9.5 
Left Front 
72 
135 
HN A-0052-E 
.09/2.3 
Right Rear 
72 
135 
HN A-0052-E 
.09/2.3 
Right Front 
81 
184 
HN A-0053-E 
.37/9.4 
Center Rear 
81 
194 
HN A-0053-E 
.37/9.5 
Center Front 
81 
194 
HN A-0053-E 
.38/9.6 
Model E36GC76EPS (36-Inch) 