Range Hood Installation
  Installation
Installation - Ducting version
After having chosen the vent option, proceed as 
follows:
 
Prepare duct and conduit cut outs as needed.
 
If possible, disconnect and move freestanding  
 
or slide-in range from cabinet opening to provide 
 
easier access to rear wall. Otherwise put a thick, 
 
protective covering over countertop, cooktop or  
 
range to protect from damage and debris. Select  
 
a flat surface for assembling the unit.   
 
 
Cover that surface with a protective covering and 
 
place all canopy hood parts and hardware in it. 
 
Determine and mark the centerline on the wall 
 
where the canopy hood will be installed. 
 
Select a mounting height comfortable for the user 
 
and mark on wall. 
   
 
Prepare duct and conduit cut outs as needed. 
 
Remove the duct knockouts using a flat blade   
 
screwdriver and a small hammer. 
 
 
 
Use the screwdriver by knocking out the pannel in  
 
similar fashion to a scalpel.   
 
 
 
Take care of sharp edges.
Vertical 
discharge
Horizontal 
discharge
Attach exhaust adaptor/damper over knockout open-
ing with three exhaust adaptor screws. Make sure 
damper pivot is nearest to top/back edge of hood.
Remove tape from damper flap.
NOTE: The exhaust adaptor/damper can be installed 
up to 1 inch on either side of the hood center to ac-
commodate offcenter ductwork. In extreme offcenter 
installations, one end of the duct connector may need 
to be trimmed to clear the electrical cable clamp.
Exhaust
transition/damper
Pivot
Top/back
edge
Top/back
edge
Exhaust
transition/damper
Pivot
Mark holes
Select the vent option that your installation will require 
and proceed to that section: 
Outside top exhaust
(Vertical duct– 3 
1
4
”x 10” Rectangular)
Use the diagram or the hood as a template and mark 
the locations on the cabinet for ductwork, electrical 
wiring and keyhole screw slots.
5/8” 
5” 
13/32” 
3-1/4” 
2-1/2” 
7-1/2” 
5” 
30” Model: 2-7/8”
36” Model: 5-3/4”  
7-7/8” 
Center line
Electrical access hole
(in cabinet bottom) 
Hood mounting 
screws (4)
Wood shims (recessed
bottom cabinets only)
Cabinet front
Vertical duct
access hole
Outside rear exhaust
(Horizontal duct– 3 
1
4
”x 10” Rectangular)
Use the diagram or the hood as a template and mark 
the locations on the cabinet for ductwork, electrical 
wiring and keyhole screw slots.
Wood shims (recessed 
bottom cabinets only)
Electrical 
access hole 
(in wall)
Center line
Cabinet 
bottom
Hood mounting 
screws (4)
Cabinet front 
21/32”
2-11/32”
30” Model: 4-15/32”
36” Model: 7”
30” Model: 6-3/8”
36” Model: 8-7/8”
3-1/4”
13/32”
5”
5”
Horizontal duct 
access hole