National Instruments 800 Series 用户手册

下载
页码 104
Appendix A
Specifications
© National Instruments Corporation
A-3
Environmental  
Note:
Random vibration profiles were developed in accordance with 
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed 
those recommended in MIL-STD-810E for Category 1 (Basic 
Transportation, Figures 514.4-1 through 514.4-3). Test report 
available upon request.
VMEbus Capability Codes
Characteristic
Specification
Temperature
0
°
 to 55
°
 C Operating; 
-20
°
 to 70
°
 C Storage
Relative 
Humidity
0% to 95% Noncondensing, Operating;
0% to 95% Noncondensing, Storage
EMI
FCC Class A Verified, EC Verified
Vibration
Operational: 5 to 500 Hz, 0.31 g, 3 axes
Non-operational: 5 to 500 Hz, 2.5 g, 3 axes
Functional Shock
MIL-T-28800E Class 3 (per Section 4.5.5.4.1)
Half-Sine Shock Pulse (11 ms duration, 30 g peak, 
3 shocks per face)
Capability Code
Description
A32, A24, A16 (master)
VMEbus master A32, A24, and A16 
addressing
A32, A24, A16 (slave)
VMEbus slave A32, A24, and A16 
addressing
D64, D32, D16, 
D08(EO)  (master)
VMEbus master D64, D32, D16, and 
D08 data sizes
D64, D32, D16, 
D08(EO)  (slave)
VMEbus slave D64, D32, D16, and 
D08 data sizes