Error Codes
If the status code display on the back of the projector shows one of the following values, 
you have encountered a likely system error requiring the attention of a qualified service 
technician. Acknowledge and clear the error by pressing EXIT twice on the rear-panel 
keypad. Try resetting the projector by powering it off, allowing it to cool and powering it on 
again. Refer to Table 5-2 and contact your dealer if the problem persists. 
The specific code number identifies the source of the error detected, and is particularly 
useful in cases where the projector is far away. For example, the code “27” means the 
lamp could not be turned on.  
AutoScope lens motor does 
not work.
• The motor is not plugged 
in or the AC outlet is not 
active.
• The motor is not 
connected to a trigger 
output on the DHD 
Controller. 
• Incorrect trigger 
assignment. 
• Ensure that the motor is 
plugged in and that the AC 
outlet is active. 
• Check the trigger 
connection between the 
lens motor and DHD 
Controller (Figure 3-13). 
• Correct the trigger 
Table 5-1. Troubleshooting Chart (continued)
Symptom
Possible Cause(s)
Solution
Table 5-2. VX-40d/-50d/-60d/-80d Error Codes 
Code
Description
General
12
Software bug. Contact dealer or Runco Technical Support. 
13
CRC error in flash ROM. Download new software. 
14
Engineering-only programming is complete. Contact Runco, replace TIPM. 
15
Attempting to download code without being in boot mode. 
16
Invalid interrupt. Power off/on. If it persists, contact dealer or Runco Technical 
Support. 
17
User forced system to stay in boot mode. 
18
Jumper for programming boot not installed. 
Note: To clear a system error, press the EXIT key (on the projector’s rear-panel keypad) twice. If 
necessary, reset the projector by powering it off, allowing it to cool and powering it on again. 
Contact your Runco dealer or Runco technical support if the error persists.