Nortel Networks 400 4.0 用户手册

下载
页码 382
224
Chapter 19 System monitoring and troubleshooting
N0060612
N0060612
Monitoring RAID disk mirror operational status using Element 
Manager
Use this procedure to monitor the primary master and mirror master hard disk activity on systems 
equipped with a RAID configuration. Use Element Manager in this procedure to monitor the 
RAID disk mirror operation.
To monitor RAID disk mirror operational status
1
Open Element Manager.
2
From the Administration tab, click System Status, and then click Disk Mirroring.
The Disk Mirroring screen displays.
3
Click on the Status tab
The Disk Mirroring screen displays the operational status of primary master and mirror master 
disks.
4
Confirm that the status for the disk mirroring activity is correct (see 
). To produce a 
status report, refer to 
Note: You must ensure the system status monitor service is running to monitor primary 
master and mirror master disk operation and disk mirroring activity.
Table 81   Status field descriptions
Status field
Description
DupliWin.dll Version
Read-only field that displays the RAID software version. The latest load always 
has the latest RAID software.
Primary Master Status
Read-only field that displays the status of the primary master disk (Passed/Failed/
NA). 
If the field indicates Passed, the drive is operating normally
If the field indicates Failed, check the power and IDE ribbon cable connections 
or replace the faulty hard disk
If the field indicates N/A (not available), check the hard disk power and IDE 
ribbon cable connections
Mirror Master Status
Read-only field that displays the status of the mirror master disk (Passed/Failed/
NA)
If the field indicates Passed, the drive is operating normally
If the field indicates Failed, check the power and IDE ribbon cable connections 
or replace the failed hard disk
If the field indicates N/A (not available), check the hard disk power and IDE 
ribbon cable connections
Rebuild
Read-only field that displays the mirror data rebuild progress (idle/started)