Nortel Networks 400 4.0 用户手册
224
Chapter 19 System monitoring and troubleshooting
N0060612
N0060612
Monitoring RAID disk mirror operational status using Element
Manager
Manager
Use this procedure to monitor the primary master and mirror master hard disk activity on systems
equipped with a RAID configuration. Use Element Manager in this procedure to monitor the
RAID disk mirror operation.
equipped with a RAID configuration. Use Element Manager in this procedure to monitor the
RAID disk mirror operation.
To monitor RAID disk mirror operational status
1
Open Element Manager.
2
From the Administration tab, click System Status, and then click Disk Mirroring.
The Disk Mirroring screen displays.
3
Click on the Status tab
The Disk Mirroring screen displays the operational status of primary master and mirror master
disks.
disks.
4
Confirm that the status for the disk mirroring activity is correct (see
). To produce a
status report, refer to
.
Note: You must ensure the system status monitor service is running to monitor primary
master and mirror master disk operation and disk mirroring activity.
master and mirror master disk operation and disk mirroring activity.
Table 81 Status field descriptions
Status field
Description
DupliWin.dll Version
Read-only field that displays the RAID software version. The latest load always
has the latest RAID software.
has the latest RAID software.
Primary Master Status
Read-only field that displays the status of the primary master disk (Passed/Failed/
NA).
NA).
•
If the field indicates Passed, the drive is operating normally
•
If the field indicates Failed, check the power and IDE ribbon cable connections
or replace the faulty hard disk
or replace the faulty hard disk
•
If the field indicates N/A (not available), check the hard disk power and IDE
ribbon cable connections
ribbon cable connections
Mirror Master Status
Read-only field that displays the status of the mirror master disk (Passed/Failed/
NA)
NA)
•
If the field indicates Passed, the drive is operating normally
•
If the field indicates Failed, check the power and IDE ribbon cable connections
or replace the failed hard disk
or replace the failed hard disk
•
If the field indicates N/A (not available), check the hard disk power and IDE
ribbon cable connections
ribbon cable connections
Rebuild
Read-only field that displays the mirror data rebuild progress (idle/started)