SECO-LARM USA SK-910RC4Q 用户手册

下载
页码 8
ENFORCER SK-910RC4Q Central Receiver 
6  
                                                      SECO-LARM U.S.A., Inc.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Setting the Timed Output: 
When a channel is set to Timed Output, triggering the channel will activate the relay for a set 
period of time. Factory default is 1 second. 
1.  The time can be set from 1~60 seconds using the Timer switches on the top of the receiver. 
2.  Set switches according to the following chart. 
NOTE: The time set via the DIP switches applies to all channels programmed for Timed Output. 
Sec. 
SW1 
SW2 
SW3 
 1* 
On 
Off 
Off 
Off 
On 
Off 
Off 
Off 
On 
On 
Off 
On 
Off 
On 
On 
10 
On 
On 
Off 
30 
Off 
Off 
Off 
60 
On 
On 
On 
*Default setting 
Setting the Auxiliary Relay: 
Each channel may be individually set to activate a separately timed 12VDC output programmable 
from 1 second to 10 minutes. The auxiliary relay provides up to 3A@12VDC*. 
1.  Connect the auxiliary device to the auxiliary relay. The two auxiliary relay terminals are the 
left-most terminals on the terminal block as shown in the diagram below.  
2.  Select which channels will trigger the auxiliary relay using the Auxiliary Relay DIP switch 
(SW8), located on the PCB as shown in the diagram below. 
3.  If the switch is in the ON position, triggering the  
corresponding channel will activate the auxiliary relay. 
4.  If the switch is in the OFF position, triggering the  
corresponding channel will not activate the auxiliary relay. 
Setting Auxiliary Relay Timer: 
1.  Output time can be adjusted from 1 second to 10 minutes  
using the auxiliary relay output time potentiometer.  
2.  Turning the potentiometer clockwise will increase the output time. 
3.  Turning the potentiometer counterclockwise will decrease the output time. 
 
Use the DIP switch to select the 
channel. Default is Channel 1 ON. 
PCB 
Auxiliary relay time potentiometer 
Terminal Block 
Auxiliary relay terminals 
Top of unit 
Timer switches 
SW1   SW2   SW3 
*Note 
Included power supply will not 
support loads larger than 500mA.  
For larger loads, replace with 
appropriate DC power supply.