For Your Safety
Caution
Before undertaking any troubleshooting, maintenance, or exploratory procedure,
carefully read the warning and caution notices.
This equipment contains voltage hazardous to human life and safety, and
can inflict personal injury.
Chassis Grounding—The PXI-1006 requires a connection from the
premise wire safety ground to the PXI-1006 chassis ground. The earth
safety ground must be connected during use of this equipment to
minimize shock hazards. See the Connecting Safety Ground
section
below.
Live Circuits—Operating personnel and service personnel must not
remove protective covers when operating or servicing the PXI-1006.
Explosive Atmosphere—Do not operate the chassis in conditions
where flammable gases are present. Under such conditions this
equipment is unsafe and may ignite the gases or gas fumes.
Modification—Do not modify any part of the chassis from its original
condition. Unsuitable modifications may result in safety hazards.
Connecting Safety Ground
Warning
The PXI-1006 chassis is designed with a three-position NEMA 15-5 style plug
that connects the ground line to the chassis ground. To minimize shock hazard, make sure
your electrical power outlet has an appropriate earth safety ground that is connected
whenever you power up the chassis.
If your power outlet does not have an appropriate ground connection, you
must connect the premise wire safety ground to the chassis grounding
screw located on the rear panel. To connect the safety ground, complete the
following steps:
1.
Connect a 16 AWG (1.3 mm) wire to the chassis grounding screw on
the rear of the chassis using a toothed grounding lug. The wire must
have green insulation with a yellow stripe or must be noninsulated
(bare).
2.
Attach the opposite end of the wire to permanent earth ground using
toothed washers or a toothed lug.