Mitsubishi Electronics DX-TL1600EM 用户手册

下载
页码 86
36
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
3. Turn the JOG dial to flash “BASIC” and turn the SHUTTLE
ring to the right.
• The sub-item stops flashing. Check that the IMAGE QUALITY
is defined correctly.
@IMAGE QUALITY     BASIC
 
MAX REC FIELDS    12.5F
 DEFINE GROUP SETTING
 By turning the JOG dial, the sub-
item of the IMAGE QLTY shown on the menu will be
changed as follows:
HIGH      SUPERIOR       BASIC 
MEDIUM      STANDARD
4. Turn the JOG dial to move the cursor to MAX REC FIELDS
and turn the SHUTTLE ring to the right.
• The sub-item will start flashing.
5. Turn the JOG dial to display “6.25F” and turn the SHUTTLE
ring to the right to define the setting.
• The sub-item will stop flashing. Check that the MAX REC
FIELDS is defined correctly.
   
@MAX REC FIELDS    12.5F
 
DEFINE GROUP SETTING
 A-REC DURATION      15S
@MAX REC FIELDS    6.25F
 DEFINE GROUP SETTING
 A-REC DURATION      15S
 By turning the JOG dial, the sub-
item of the MAX REC FIELDS shown on the menu
will be changed as follows:
25F     12.5F     8.33F      6.25F 
1F     2.5F      4.17F     5F 
 The underlined items cannot be selected when
the MOTION DETECTION setting is active.
 When the MOTION DETECTION setting in the
INITIAL SET UP menu is turned ON, the MAX REC
FIELDS for each time setting will be automatically
altered as follows. These settings will not automati-
cally revert to their former values even if MOTION
DETECTION is turned OFF.
Case of <NORMAL REC SETTING> menu and <A-
REC/M-DET SETTING> menu.
“25F” 
}
 “12.5F”, “8.33F” 
}
 “6.25F” , “5F” 
}
 “4.17F”
Case of “MODE” in the <TIMER PROGRAM> menu.
“25” 
}
 “12.5”, “8.33” 
}
 “6.25” , “5” 
}
 “4.17”
6. Turn the JOG dial and move  the cursor to “DEFINE GROUP
SETTING” and turn the SHUTTLE ring to the right .
• The <DEFINE ALARM GROUP> menu appears.
<DEFINE ALARM GROUP>
CH PRI FILD  CH PRI FILD
@Q  1  0.39   O    1    0.39
  W  1  0.39   P    1    0.39 
  E  1  0.39   {    1    0.39 
  R  1  0.39   }    1    0.39 
  T  1  0.39   q    1    0.39 
  Y  1  0.39   w    1    0.39 
  U  1  0.39   e    1    0.39 
  I  1  0.39   r    1    0.39 
7. Check that the cursor is next to the CAMERA CH.
1
 and
turn the SHUTTLE ring to the right.
• The sub-item will start flashing.
Various recording settings (continued)
<DEFINE ALARM GROUP>
CH PRI FILD  CH PRI FILD
@Q  1  0.39   O    1    0.39
  W  1  0.39   P    1    0.39 
  E  1  0.39   {    1    0.39
  R  1  0.39   }    1    0.39 
  T  1  0.39   q    1    0.39 
Y
1
0 39
w
1
0 39
8. Turn the JOG dial to display “ 5 ” then turn the SHUTTLE
ring to the right.
• The “-” is now selected.
<DEFINE ALARM GROUP>
CH PRI FILD  CH PRI FILD
@Q  5  0.07   O    1    0.39
  W  1  0.39   P    1    0.39 
  E  1  0.39   {    1    0.39 
  R  1  0.39   }    1    0.39 
  T  1  0.39   q    1    0.39 
Y
1
0 39
w
1
0 39
9. Repeat Step 7 and 8 setting CAMERA CH.
and
 
turn the
SHUTTLE ring to the right .
• The sub-item will stop flashing. Check that the CAMERA
CH. is defined correctly.
<DEFINE ALARM GROUP>
CH PRI FILD  CH PRI FILD
  Q  5  0.08   O    1    0.41
  W  1  0.41   P    1    0.41
  E  1  0.41   {    1    0.41 
  R  1  0.41   }    1    0.41 
@T  -         q    1    0.41
  Y  1  0.41   w    1    0.41
  U  1  0.41   e    1    0.41  
  I  1  0.41   r    1    0.41
 When the “ - ” is assigned, the camera is disabled.
 By turning the JOG dial, the sub-
item of the priority shown on the menu will be
changed as follows:
1      2      3
-       5      4
 The define group settings for normal recording
have to be set on the DEFINE GROUP SETTING in
the <NORMAL REC SETTING> menu. For details
of settings for recordings, please refer to page 14.
10. Turn the SHUTTLE ring to the left.
• The <A-REC/M-DET SETTING> menu will appear.
11. Turn the JOG dial to move the cursor to A-REC DURATION
and turn the SHUTTLE ring to the right.
• The sub-item will start flashing.
12. Turn the JOG dial to display “5M” and turn the SHUTTLE
ring to the right to define the setting.
• The sub-item will stop flashing. Check that the A-REC
DURATION is defined correctly.
     
@A-REC DURATION      15S
 
RECORD ALARM        ALL
 PRE A-REC
@A-REC DURATION       5M
 
RECORD ALARM        ALL
 PRE A-REC
  “MAN”: Alarm recording continues until the
ALARM IN terminal is cleared.
 By turning the JOG dial, the sub-
item of the A-REC DURATION shown on the menu
will be changed as follows:
15S     30S     45S     1M     2M     5M
  10S     5S     2S     MAN     10M