Siemens IPC427C 用户手册
SIMATIC IPC427C
All rights reserved
© Copyright Siemens AG 2013
3/5
Monitoring functions
Temperature
• Processor temperature
• Motherboard
• Messages can be evaluated by the
application program
Watchdog
• Monitoring of program execution
• Monitoring time can be parameter-
ized in software
• Can be parameterized for a fault or
restart
• Messages can be evaluated by the
application program.
Monitoring functions via
the network
the network
• DiagBase
• SIMATIC PC DiagMonitor
Remote monitoring capability for:
• Watchdog
• Temperature
• Mass memory monitoring (SMART)
• System / Ethernet monitoring
(Heartbeat)
• Runtime meter
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in SIMATIC soft-
ware
• Configuration of client/server archi-
tectures
• Layout of log files
Ambient conditions
Degree of protection to
EN 60529 (front/rear)
EN 60529 (front/rear)
IP20
Vibration load during
operation
operation
Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to: IEC 60068-2-6,
Test Fc
• Devices without drive:
- 5-9 Hz, 3.5 mm deviation, 10x /axis,
1 octave/min
- 9-150 Hz, 9.8 m/s
2
, 10x /axis,
1 octave/min
Devices with hard disk: Wall mounting
• Requirements according to:
IEC 61131-2
• Tested according to: IEC 60068-2-6,
Test Fc
• 10 ... 58 Hz, 0.0375 mm deviation,
10x /axis, 1 octave/min
• 58 ... 200 Hz, 4.9 m/s
2
, 10x /axis,
1 octave/min
Shock loading during
operation
operation
Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to: IEC 60068-2-27,
Test Ea
• Module/rack: 150 m/s
2
, power-up,
11 ms shock duration
Devices with hard disk: Wall mounting
• Requirements according to:
IEC 61131-2
• Tested according to: IEC 60068-2-27,
Test Ea
• Devices with drive: 50 m/s
2
, power-
up, 30 ms shock duration
Electromagnetic
compatibility (EMC)
compatibility (EMC)
• Emitted interference
EN 55022 Class B
• Interference immunity,
burst
EN 61000-6-2 or IEC 61131-2:
• 2 kV - Tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetrical
- Tested acc. to IEC 61000-4-5
• Interference immunity,
surge
1 kV to IEC 61000-4-5; symmetrical
2 kV to IEC 61000-4-5; asymmetrical
• ESD interference
immunity
According to NAMUR Recommenda-
tion NE 21 and EN 61000-6-2:
tion NE 21 and EN 61000-6-2:
• 6 kV contact discharge - Tested acc.
to IEC 61000-4-2
• 8 kV air discharge - Tested acc. to
IEC 61000-4-2
• Immunity to high radio
frequency interference
According to EN 61000-6-2 or
IEC 61131-2:
IEC 61131-2:
• Interference immunity 80 ... 1000
MHz: 10 V/m with 80% AM (1 kHz);
tested acc. to IEC 61000-4-3;
tested acc. to IEC 61000-4-3;
• 1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3
to IEC 61000-4-3
• Immunity to high-fre-
quency current feed
Acc. to NAMUR Recommendation NE
21 and EN 61000-6-2 or IEC 61131-2:
21 and EN 61000-6-2 or IEC 61131-2:
• 10 kHz ... 80 MHz: 10 V with 80% AM
(1 kHz) tested acc. to IEC 61000-4-6
• Immunity to magnetic
fields
Acc. to NAMUR Recommendation NE
21 and EN 61000-6-2 or IEC 61131-2:
21 and EN 61000-6-2 or IEC 61131-2:
50/60 Hz; 100 A/m rms value - tested
acc. to IEC 61000-4-8
acc. to IEC 61000-4-8
Ambient temperature dur-
ing operation
ing operation
• 0 ... 55 ºC with flash drive/SSD
(horizontal; preferred mounting
position; with derating)
position; with derating)
• 0 ... 50 ºC with flash drive/SSD
(horizontal; preferred mounting
position; maximum configuration)
position; maximum configuration)
• 0 ... 50 ºC with flash drive/SSD
(vertical)
• 5 ... 40 ºC with hard disk (horizontal
and vertical)
Moist heat
• With CompactFlash card/SSD: 95 %
• With hard drive 80%
© Siemens AG 2013