Carrier 30MPA 用户手册

下载
页码 16
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53300054-01
Printed in U.S.A.
Form 30MP-1SI
Pg 16              910
        1-10
Replaces: New
Copyright 2010 Carrier Corporation
Fi
g.
 1
6
 — 
T
y
pic
a
l Lo
w V
o
lta
g
e Contr
o
Wi
ri
ng
NO
TES
:
1.
F
act
or
y wir
in
is in 
a
c
cor
dance with
 UL 
1
995 st
an
dard
s
Field
 modi
ficat
ion
s or addit
ion
s m
ust
 b
e in
comp
liance wit
a
ll appli
c
a
b
le
 code
s
.
2.
A
ll unit
s
 or
 mod
u
les ha
v
e
 singl
p
o
int
 p
rima
ry po
w
e
r conne
ct
ion
. Main po
w
e
m
u
st 
b
e suppl
ied
fr
om a f
ield or f
act
or
y supp
lied disconne
ct
.
3.
Wi
ri
ng
 f
o
ma
in fie
ld su
pply m
ust 
b
ra
te
d 7
C
. Use 
co
pper
 cond
ucto
rs on
ly
.
a
.
In
comin
g
 wire siz
e
 r
a
nge f
o
r te
rmina
b
lo
c
k
 wit
h MCA u
p
 t
o
 120 a
mps is 14 A
W
G
 (Amer
ican
Wi
re Gage
) to 2/
0.
b
.
Incomin
g wire
 siz
e
 r
a
nge 
fo
te
rminal
 b
loc
k
 wit
h MCA
 f
rom 1
20.
1 amp
s
 to
 31
0 amp
s
 is 6 
A
W
G
to
 3
5
0
 kcm
il.
c.
In
comin
g
 wire 
siz
e
 r
ange
 f
o
non-f
u
sed
 disconne
ct
 wit
h MCA u
p
 t
o
 50 
amps is 10 
A
W
G t
o
2 A
W
G.
d
.
In
comin
g
 w
ire si
z
e
 r
a
nge f
o
n
on-f
u
sed disconn
ec
t wit
MCA
 f
rom 50
.1 amp
s
 t
o
 90 amps  
is 6
A
W
G to 3/
0.
e
.
In
comin
g
 wir
e siz
e
 r
ang
e f
o
r n
on-f
u
sed 
disconne
ct
 w
ith 
MCA 
fro
m
 90
.1
 amps 
to
 25
0 a
m
p
s
  i
s
 4
A
WG to 35
k
c
m
il.
4.
Re
fe
r t
o
 ce
rt
if
ied di
mensiona
l dr
a
wings f
o
e
x
ac
lo
cati
ons of
 t
he ma
in po
w
e
a
nd cont
rol p
o
w
e
r
e
ntr
ance locat
ion
s
.
5.
T
e
rm
inal 24
 of
 th
e L
V
is
 f
o
r cont
rol
o
f chill
ed w
a
ter
 pu
mp (CWP) sta
rt
e
r.
 T
e
rm
inal 20 of
 the
 L
V
is
for cont
rol
 of
 co
nden
se
r pump
 (CNP) st
ar
ter
 or con
denser 
fan re
la
y (
C
F
R
).
 The
 maxim
um lo
ad
a
llo
w
ed f
or
 t
he rel
a
ys 
is
 5 V
A
 sea
led.
 1
0 V
A
 inr
ush at
 24
 V
A
C
Fie
ld po
w
er suppl
y is 
re
q
ui
red.
6.
T
e
rminal 2
5
 of
 L
V
T is 
fo
r an a
lar
m re
la
y.
 The
 maxim
u
m loa
d
 allo
w
e
d f
o
r al
ar
m rel
a
y is  5 V
A
 se
aled
,
1
0 V
A
 inr
ush 
at
 24
 V
A
C
. Fie
ld 
po
w
er 
suppl
is n
ot
 re
q
uire
d.
7.
Ma
k
e app
ropr
ate
 co
nnect
ions to
 L
V
T as 
sho
w
n
 f
or ene
rgy manag
ement
 b
oar
d opt
ion
s
. T
h
e co
n-
tact
s f
or deman
limit and
 ice done opt
ion
s
 m
ust
 b
ra
te
d
 f
o
r dr
y circuit
 a
pplicat
ion
 capa
b
le of
 ha
n-
d
ling 24 V
A
C
 loa
d up to 50
 mA.
 In
st
alla
tio
n of opt
ion
al ener
gy 
man
ageme
nt 
b
o
a
rd re
q
uired
.
8
.
R
em
ov
e
 j
u
m
p
er
 b
et
w
een 
te
rmina
ls
 16 
and
 17
 when
 f
ield
 chille
d w
a
te
pump
 int
e
rl
oc
k (
C
WPI
) is
instal
led.
9.
T
e
rminals 1
8
 an
d 19 
of 
LV
T are
 f
or f
loa
tin
g po
int
 co
nt
rol o
f con
denser 
w
a
ter
 v
a
lv
e
 (CWV)
. T
emi
nal
1
8
 co
mmands v
a
lv
e clo
s
e
d
T
e
rminal 19
 comma
nds v
a
lv
e
 o
pen.
 The maxim
u
m loa
d
 allo
w
e
d f
o
r
con
denser
 w
a
te
r v
a
lv
e
 is 5.
5 V
A
 at
 24 V
A
C
. Field po
w
e
sup
p
ly 
is not
 re
q
ui
red.
 
1
0
.
A
ll discret
input
a
re 24 V
A
C
.
                  
       LEGE
N
D
AL
MR
— 
Alar
m Rela
y (24 V) 5 V
A
 Max
AW
G
— Amer
ican 
Wire 
Gage
CF
R
— 
Condenser F
an
 Rela
y
CNF
S
C
ondenser Flo
w
 Switch
CNP
— Condenser 
P
u
mp
CNPI
— 
Condenser P
u
mp Inter
loc
k
CWP
— 
Chil
led W
a
ter
 Pump
CWPI
— 
Chilled W
a
ter Pump Inte
rl
oc
k
CWV
— 
Condenser W
a
ter V
a
lv
e
EMM
— 
Energy Manageme
nt Module
LV
T
— 
Lo
w V
oltage T
er
m
inal Str
ip
NEC
N
ational E
lectr
ica
l Cod
e
OA
T
— 
Out
s
ide Air T
emp
er
ature
SPT
— Space
 T
emper
atu
re
a30-5039