Industio CI-134 Series User’s Manual
Hardware Installation with IO-IRQ Utility
This section is for those who can not use quick hardware installation:
Install two or more 
Industio CI-134 Series boards in a system.
Fail to install, due to the I/O address 0xA700 is not available or has conflict in the system.
Use operating systems other than Windows NT and 95/98.
Before proceeding to the softwar e (dr iver ) installation, detailed in the next chapter,
“Software Installation”, do har dwar e configur ation to setup the I/O and IRQ with
“Io-ir q.exe”, detailed in the next section.
Remember to keep the hardware settings in mind for the software installation.
Because the ASIC-designed 
Industio CI-134 Series has no switch and no jumper for
manually configuring the I/O address, IRQ, INT Vector, etc. of the boards, you must
run  the  software  utility,  Io-ir q.exe,  in  the  driver  diskette  under  DOS  system  to
change the hardware configuration.
1. Choose a PC that has DOS system inside.
2. Power off the PC.
3. Make sure no hardware conflict and plug the board in a free 16-bit slot of the PC,
one boar d at a time with J P1 open.
If  you  are  installing  multiple  boards,  insert  one  board  at  a  time  and
configure it using the Io-irq program before inserting the next board.
This  is  to  prevent  conflict  between  two  boards  with  same  default
hardware settings.
The 
Industio CI-134 Series has the following default (factory) settings,
I/O address: 0x180 (1st port), 0x188 (2nd port), 0x190 (Port 3), 0x198
(Port 4)
IRQ: 10
INT Vector: 0x1C0
Configuration Access Port (CAP): 0x180