Troubleshooting
Common 
Industio CI-134 Series problems and possible solutions are listed below. If
you still have problems, contact your dealer or Moxa for help. Or use the “Pr oblem
Repor t For m
” at the end of this manual to report problems to your dealer at once for
faster technical support.
General Troubleshooting
1. The MOXA dr iver , while installing the dr iver , cannot detect the MOXA boar d.
Hardware causes and solutions:
a. The board is not installed or missing (absent). Please install it.
b.  The board is not properly plugged in the system. If that is the case, re-install
the board and make sure that it fits well in a 32-bit slot this time. Sometimes
the slot for plugging the board is bad. In this case, try other slots until you find
a good one.
2. The  MOXA  boar d  and  dr iver   ar e  activated  but  cannot  tr ansfer
(tr ansmit/r eceive) data.
Hardware Causes and Solutions:
a. Check  for  wrong  cable  wiring.  Refer  to  the  “Connection  Cable  and  Cable
Wiring” chapter for precise pin outs of the connector type you are using.
b. The cable or the board is defective. You may use other ports, cables or boards
to verify. In addition, the 
PComm “Diagnostic” utility for Windows NT and
Windows  95/98  is  good  for  testing  MOXA  boards  and  port  conditions.  If
Diagnostic reports error, replace the faulty components.