Bosch D9412GV2 用户手册
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation
.
Bosch Security Systems, Inc. | 5/05 | F01U003641B
15
4.0 Installation
4.1 Installation
Preparation
This section contains a general installation procedure
and refers to other sections of the document for
detailed instructions.
and refers to other sections of the document for
detailed instructions.
Review this document and the D9412GV2/D7412GV2
Program Entry Guide (P/N: F01U003636) before
beginning the installation to determine the hardware
and wiring requirements for the features used.
Program Entry Guide (P/N: F01U003636) before
beginning the installation to determine the hardware
and wiring requirements for the features used.
Have the following documentation available when
reading through this guide:
reading through this guide:
•
D9412GV2/D7412GV2 Program Record Sheet
(P/N: F01U003635)
(P/N: F01U003635)
•
Security System Owner’s Manual
(P/N: 71-06633-000) and Security System Owner’s
Manual Supplement (P/N: 33267)
(P/N: 71-06633-000) and Security System Owner’s
Manual Supplement (P/N: 33267)
•
Command center (keypad) installation manual
(D1255, D1256, D1257, D1260, or D720)
(D1255, D1256, D1257, D1260, or D720)
Before installation, become familiar with the operation
of the D5200 Programmer or the RPS.
of the D5200 Programmer or the RPS.
4.2 Enclosure
Options
Mount the control panel assembly in any of the Bosch
Security Systems enclosures listed:
Security Systems enclosures listed:
•
D8103 Universal Enclosure (tan)
•
D8109 Fire Enclosure (red)
•
D8108A Attack Resistant Enclosure (tan)
Refer to the D9412GV2/D7412GV2 Approved
Applications Compliance Guide (P/N: F01U003639)to
determine if the application requires a specific
enclosure.
Applications Compliance Guide (P/N: F01U003639)to
determine if the application requires a specific
enclosure.
4.3 Mounting
Enclosure
1.
Run the necessary wiring throughout the premises.
2.
Mount the enclosure in the desired location. Use
all five enclosure mounting holes. Refer to Figure 2.
all five enclosure mounting holes. Refer to Figure 2.
3.
Pull the wires into the enclosure.
Electro-Magnetic Interference (EMI) can cause
problems on long wire runs. Refer to EMI on Long Wire
Runs in the D9412GV2/D7412GV2/D7212GV2
Installation and Troubleshooting Quick Reference Guide
(P/N: F01U003638).
problems on long wire runs. Refer to EMI on Long Wire
Runs in the D9412GV2/D7412GV2/D7212GV2
Installation and Troubleshooting Quick Reference Guide
(P/N: F01U003638).
Figure 2:
Enclosure Mounting
8
2
1
3
2
4
3
7
5
9
6
1 - Point chart label
2 - Mounting skirt hooks (2)
3 - Module mounting holes (12)
4 - Tamper switch mounting holes (5)
5 - Skirt mounting hole (1)
6-
Enclosure mounting holes (5)
7 - Mounting skirt hook holes (2)
8 - Back of D9412GV2/D7412GV2 Control Panel
9 - Lock down tab