Weber 675 说明手册

下载
页码 16
13
CHECK FOR GAS LEAKS
Manifold
a)
c)
b)
d)
Manifold
Check for leaks by wetting the connections with the soap
and water solution and watching for bubbles. If bubbles
form or if a bubble grows there is a leak.
Note - Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.
WA R N I N G : D o n o t i g n i t e bu r n e rs when leak ch e ck i n g .
Manifold
Manifold
Summit 475
Figure 24
Summit 675
Figure 24
a)
d)
c)
Check:
a) Left valves to manifold connection. Figure 24 (a).
b) Center valves to manifold connection. Figure 24 (b).
(For Summit 675 only.)
c)
Right valves to manifold connection. Figure 24 (c).
d)
Gas line to manifold connection. Figure 24 (d)
e) Leak check all gas supply connections.
WARNING: If there is a leak at connection 24 (d), turn
OFF the gas and retighten the fitting with a wrench
and recheck for leaks with soap and water solution.
If a leak persists after retightening the fitting, turn
OFF the gas. DO NOT OPERATE THE BARBECUE.
Contact your dealer.
WARNING: If there is a leak at connections 
24 (a), 24 (b), or 24 (c) turn OFF the gas. Do not
operate the barbecue. Contact your dealer.
When leak checks are complete, turn gas supply OFF at
the source and rinse connections with water.
To regulator
To regulator