Desa T32p-a SERIES 用户手册

下载
页码 44
www.desatech.com
116646-01D
35
pOSSIbLE CAUSE
1. Gas  leak.  See  Warning 
statement above 
1. Gas  leak.  See  Warning 
statement above 
2. Control valve defective
1. Gas  leak.  See  Warning 
statement above
1. Improper log placement
2. Air  holes  at  burner  inlet 
blocked
3. Burner flame holes blocked
4. Improper venting or excessive 
blockage
5. Excessive amounts of embers 
and pan material
REMEDY
1. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 21)
1. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 21)
2. Replace control valve
1. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 21)
1. Properly locate logs (see In-
stalling Logs, Lava Rock and 
Glowing Embers, page 25)
2. Clean out air holes at burner 
inlets. Periodically repeat as 
needed
3. Remove blockage or replace 
burner
4. Have the vent system inspect-
ed, including the termination 
cap. Remove any restrictions 
or obstruction
5. Clear excess embers until a 
minimum gap of 1/2" remains 
under the grate 
ObSERvED pRObLEM
Fireplace  produces  unwanted 
odors
Gas  odor  even  when  control 
knob is in OFF position
Gas odor during combustion
Dark residue on logs or inside 
of fireplace
TROUblEShOOTING 
Continued 
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.