To adjust Sensitivity: 
1. From the Sonar Page, press 
MENU
|
ENT
2. The Sensitivity Control Bar appears. Press 
↓ to decrease sensitivity; 
press 
↑ to increase sensitivity. When it's set at the desired level, press 
EXIT
. (When you reach the maximum or minimum limit, a tone sounds.) 
To turn off HyperScroll: 
1. From the Sonar Page, press 
MENU
|
↓ to 
P
ING 
S
PEED
|
ENT
2. The Ping Speed Control Bar appears. Press 
↓ to decrease ping speed 
to 50 percent. When it's set at the desired level, press 
EXIT
When you enable HyperScroll, the width of the FasTrack bar graph 
display doubles in width at the right side of the screen, giving you a 
better view of Fastrack's instantaneous sonar returns. 
Reset Options 
This command is used to reset all features, options 
and settings to their original factory defaults. This 
is useful when you have changed several settings 
and want to return the unit to basic automatic op-
eration. 
1. Press 
MENU
|
MENU
|
↓ to 
S
YSTEM 
S
ETUP
|
↓ to 
R
ESET 
O
PTIONS
|
ENT
2. Press 
↑ or ↓ to 
Y
ES
|
ENT
3. All features and options are returned to the factory default settings. 
Sensitivity & Auto Sensitivity 
The sensitivity controls the ability of the unit to pick up echoes. A low 
sensitivity level (from zero to 50 percent) excludes much of the bottom 
information, fish signals, and other target information. High sensitivity 
levels let you see this detail, but it can also clutter the screen with many 
undesired signals. Typically, the best sensitivity level shows a good solid 
bottom signal with Colorline and some surface clutter. 
Automatic Sensitivity 
This unit has two sensitivity modes: Automatic and Manual. In auto-
matic you can adjust sensitivity up to 100 percent but the unit will 
limit your minimum setting.  
In manual mode, you have complete control over sensitivity, with the 
ability to set it anywhere from zero to 100 percent.