L200 Inverter
Oper
ations
and Monitor
ing
4–57
Having two motor profiles lets you store two “personalities” for motors in one inverter’s 
memory. The inverter allows the final selection between the two motor types to be made 
in the field through the use of an intelligent input terminal function [SET]. This provides 
an extra level of flexibility needed in particular situations. See the following table.
Parameters for the second motor have a function code of the form x2xx. They appear 
immediately after the first motor’s parameter in the menu listing order. The following 
table lists the parameters that have the second parameter register for programming.
Function Name
Parameter Codes
1st motor
2nd motor
Multi-speed frequency setting
A020
A220
Acceleration (1) time setting
F002
F202
Deceleration (1) time setting
F003
F203
Acceleration (2) time setting
A092
A292
Deceleration (2) time setting
A093
A293
Select method to use Acc2/Dec2
A094
A294
Acc1 to Acc2 frequency transition point
A095
A295
Dec1 to Dec2 frequency transition point
A096
A296
Level of electronic thermal setting
B012
B212
Electronic thermal characteristic
B013
B213
Torque boost select
A041
A241
Manual torque boost value
A042
A242
Manual torque boost frequency adjustment
A043
A243
V/f characteristic curve selection
A044
A244
iSLV voltage gain
A046
A246
iSLV slip compensation
A047 
A247
Base frequency setting
A003
A203
Maximum frequency setting
A004
A204
Frequency upper limit setting
A061
A261
Frequency lower limit setting
A062
A262
Motor capacity
H003
H203
Motor poles setting
H004
H204
Motor stabilization constant
H006
H206