Hitachi L200 用户手册
L200 Inverter
Appendix B
B–19
ModBus Data Listing
ModBus Coil List
The following tables list the primary coils for the inverter interface to the network. The
table legend is given below.
table legend is given below.
• Coil Number - The network address to the coil, which is a single bit (binary) value
• Name - The functional name of the coil
• R/W - The read-only (R) or read-write (R/W) access permitted to the inverter data
• Description - The meaning of each of the states of the coils
List of Coil Numbers
Coil
Number
Name
R/W
Description
0000h
(Reserved)
R
—
0001h
Run command
R/W
0..... Stop
1..... Run (enabled when A003=03)
1..... Run (enabled when A003=03)
0002h
FW/REV command
R/W
0..... REV
1..... FW (enabled when A003=03)
1..... FW (enabled when A003=03)
0003h
External trip (EXT)
R/W
0..... No trip event
1..... Trip occurred
1..... Trip occurred
0004h
Trip reset (RS)
R/W
0..... No reset condition
1..... Reset
1..... Reset
0005h
(Reserved)
R
—
0006h
(Reserved)
R
—
0007h
Intelligent input terminal 1
R/W
0..... OFF *1
1..... ON
1..... ON
0008h
Intelligent input terminal 2
R/W
0009h
Intelligent input terminal 3
R/W
000Ah
Intelligent input terminal 4
R/W
000Bh
Intelligent input terminal 5
R/W
000Dh
(Not used)
—
—
000Eh
Run/Stop status
R
0..... Stop (corresponds to D003 monitor)
1..... Run
1..... Run
000Fh
FW/REV status
R
0..... FW
1..... RV
1..... RV
0010h
Inverter ready
R
0..... Not ready
1..... Ready
1..... Ready
0011h
(Reserved)
R
—
0012h
(Reserved)
R
—
0013h
(Reserved)
R
—