MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Lines/Trunks 
Page 3-47
Selecting Line/Trunk Options 
3
The primary, secondary and tertiary clock sources, all three of which should be 
programmed if possible, should be set in the following order:
1.
The loop clock sources on BRI ports with DSLs in service. If at all possible, 
all three clock sources should be on the same 800 NI-BRI module.
2.
The loop clock source on any 100D module connected to the CO and in 
service.
3.
The loop clock source on any 100D module in T1 mode operating in a 
tie-trunk configuration.
4.
The local clock source on any 100D module.
If no administration has been performed, upon Frigid Start (system start-up), the 
first 100D or NI-1 BRI port that is in service will be the default primary loop clock 
source.
NOTE:
NOTE:
NOTE:
Extra BRI DSLs which are not in service should never be programmed as 
clock sources.
Planning Form Instructions
3
Refer to Form 1, System Planning, Control Unit Diagram. Complete the following 
information on Form 3i, Incoming Trunks: BRI Options (800 NI-BRI Module), 
page 2: 
1.
To keep the factory setting (the first slot and port found in the system 
provides synchronization for the system), or if assigning a different module 
to provide primary clock synchronization:
Enter the slot and/or DSL number (BRI only) under “Primary Clock 
Synchronization.”
Under the “Source” subheading, check “Loop” to indicate that the 
system uses the clock of the far-end connection (factory setting) or 
“Local” to indicate the clock is free-running (100D modules only).
NOTE:
The only option for an 800 NI-BRI module is loop, which is 
automatically assigned and is not programmable.
2.
If assigning secondary or tertiary backup synchronization:
Enter the slot and DSL number (BRI only) under “Secondary Clock 
Synchronization” and/or “Tertiary Clock Synchronization.”
Under the “Source” subheading in each column, check “Loop” to 
indicate that the system uses the clock of the far-end connection 
(factory setting) or “Local” to indicate the clock is free-running 
(100D modules only).
NOTE:
The only option for an 800 NI-BRI module is loop, which is 
automatically assigned and is not administrable.