Lucent Technologies 6.1 用户手册

下载
页码 588
MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Features 
Page 4-27
Group-Assigned Features 
4
Call Pickup Groups
4
This section contains instructions for assigning this feature to employees who 
work in a common area and who do not have a support person for coverage. You 
can assign up to 30 call pickup groups with up to 15 telephones for each group. 
Each telephone can be assigned to only one group.
NOTE:
NOTE:
NOTE:
This feature is similar to the Coverage feature presented later in this 
chapter. Compare these features before choosing the appropriate feature 
for the system.
Planning Form Instructions
4
1.
Form 7a holds the programming information for eight Call Pickup groups. 
Make additional copes of the form if more groups are planned. Review the 
analysis of question 10 on the Employee Communication Survey, and 
determine the number of call pickup groups needed (maximum of 30).
2.
For each group, write the group number in the Group Number space. Start 
with 
1
 and number the groups sequentially.
3.
Write the name of a group, such as Customer Service in the Group ID 
space (see the survey analysis).
4.
Write the extension number for each group member in the Ext. No. column 
(see Form 2a).
5.
Write each group member’s name or location in the Person or Location 
column (see Form 2a).
Group Paging
4
This section contains instructions for setting the system to allow users to make 
voice announcements that are heard by a particular group of employees with 
speakerphones or by everyone who has a speakerphone.
You can assign six paging groups of selected employees, such as secretarial 
pools, committee members, or departments, who need to hear announcements. 
Each group can have as many as 10 extension numbers.
The seventh paging group is factory-set to page all extension numbers. This 
group is useful if the system does not have a loudspeaker paging system.
The system automatically reserves extension numbers 793–799 for paging 
groups. Extension 799 is the Page All group. Decide whether to keep or to 
reassign the factory-set extension numbers. Keep in mind that you can provide 
one-touch use of Group Paging to operators with DSSs if you renumber to 
extensions within the Page 1, 2, or 3 button ranges or set the Page 12, or 3 
buttons so the operators can access them.