MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Features 
Page 4-49
System Features 
4
Recall Timer
4
This section contains instructions for designating the length of the switchhook 
flash sent when Recall is used to disconnect a call and receive a new dial tone 
without hanging up. The interval of the switchhook flash and how Recall works 
depends on the type of telephone being used.
For multiline telephones, the factory setting is 450 ms. If users experience 
difficulty with Recall, the interval can be changed to a longer or shorter interval. 
The single-line telephone Flash or Recall button transmits a timed switchhook 
flash of about half a second.
Planning Form Instructions
4
Under the Recall Timer heading on Form 8a, check 
one of the following:
350 ms
450 ms (factory setting)
650 ms
1 sec
Interdigit Timers
4
Programming for interdigit timers is reserved for Lucent Technologies technical 
support personnel or authorized dealers.
Interdigit timers are used by the MERLIN LEGEND system to determine when a 
user originating an outside call has completed dialing the digits. The information is 
necessary to allow the system to perform subsequent operations. You should not 
change the factory settings for interdigit timers unless instructed to do so by 
Lucent Technologies technical support or by an authorized dealer.
Rotary
4
This section contains instructions for designating whether dialed digits on 
rotary-dial lines/trunks are sent one by one as they are dialed or are stored and 
sent when dialing is completed.
Planning Form Instructions
4
Under the Rotary heading on Form 8a, check 
one of the following:
To store digits and send them when dialing is completed, check the Delay 
(factory setting) box.
To send digits out as they are dialed, check the No Delay box.