   5 COORDINATE MEASUREMENT
5
COORDINATE MEASUREMENT
5.1
Setting Coordinate Values of Occupied Point 
Set the coordinates of the instrument (occupied point) according to coordinate origin, and the 
instrument automatically converts and displays the unknown point (prism point) coordinates following 
the origin.
It is possible to retain the coordinates of the occupied point after turning the power off. 
Refer to Chapter 16 “SELECTING MODE”.
Operating procedure
Operation
Display
1
Press the [F4](
) key from the coordinate 
measurement mode to get the function on page 2.
[F4]
2
Press the [F3](OCC) key.
[F3]
3
Enter N coordinate value. *1)
[F1]
Enter data
[F4]
4
Enter E and Z coordinate values in the same 
manner.
After entering the values, the display returns 
coordinate measuring display.
Input range  –99999999.9990 
N,E,Z
 +99999999.9990 m
                    –99999999.999  
N,E,Z
  +99999999.999   ft.
                    –99999999.11.7 
N,E,Z
  +99999999.11.7  ft.+inch
N
E
z
n
e
Prism (n,e,z)
Inst.PointC
Origin(0,0,0)
 N:      123.456 m
 E:       34.567 m
 Z:       78.912 m
MEAS  MODE  NP/P P1
R.HT INSHT  OCC  P2
 N
       0.000 m
 E:       0.000 m
 Z:       0.000 m
INPUT --- --- ENTER  
1234 5678 90. –[ENT]
 N:     -72.000 m
 E
       0.000 m
 Z:       0.000 m
INPUT --- --- ENTER
  
 N:       51.456 m
 E:       34.567 m
 Z:       78.912 m
MEAS MODE  NP/P  P1
<
<
<
<
<
<