3M 965AMS 用户手册

下载
页码 204
 
201
3M™ Dynatel™ Advanced Modular System 965AMS 
Specifications
Electrical Specifications
Functions
Range 
Resolution
Accuracy
Caller ID (U.S. and 
Canada only)
Carrier level
Date, time,  
number, name
 -4 to –32 dBm
1 dBm 
±2 dBm
Short range wideband specifications (without SA option)
Wideband loss  
100, 135 Ω Zin
Wideband tone 
output–100,135 Ω Zout
-50 to +2 dBm,  
20 kHz to 1.2 MHz
0 dBm, 20 k to 2.2 MHz
0.1 dB, 100 Hz
1 kHz
±2 dB, 1% Hz 
±+1 dB
SA wideband specifications (with SA option)
Wideband loss  
100, 135 Ω Zin
-85 to +5 dBm,  
20 kHz to 2.2 MHz
0.1 dB, 100 Hz
±1 dB, 1% Hz 
Wideband noise metallic
100, 135 Ω Zin
E, F, G & G2 filters
E filter 10-90 dBm 
F filter 20-90 dBm
G filter 30-90 dBm
1 dB
1 dB
1 dB
±2 dB
±2 dB
±2 dB
Wideband spectral analysis 
100, 135 Ω Zin
Dynamic range
Wideband tone output 
–100,135 Ω Zout
10 kHz to 2.2 MHz
–90 dBm to +10 dBm
0 dBm, 20 kHz to 
2.2 MHz
0.5% of span
1 dB
1 kHz
1%
±1 dB
±0.1% frequency 
±0.5 kHz 
Impulse noise counting 
E, F, G & G2 filters
Counting interval
1-60 minutes
1 minute
±5%
Threshold
Lower limits: 30 dBrnC 
& E
40 dBrnF  
 
50 dBrnG  
 
100 dBrn upper limit  
All 30 dB higher for N to 
Ground
1 dB
±1 dB (typical)
Count capacity
9999
1
Filters:
C, E, F, G, G2  
and Psophometric 
for OUS
E filter
F filter
G filter
G2 filter
300 Hz – 3400 Hz 
1 kHz – 50 kHz
4.9 kHz – 245 kHz
20 kHz – 1.1 MHz – 3 dB points
20 kHz – 2.2 MHz
Stored results  
(All Results)
100 results total of all 