3
Design Information
36
″ Refrigerators, Freezers
Flush or
Semi-Flush
Enclosure
Installations
Side Panel Requirements:
• Side panels are not required whenever the 
refrigerator is installed into an enclosure or
between pantry and oven cabinets.
• Side panels are required whenever the sides of the
refrigerator are exposed.
• Side panel sizes vary depending on the type of 
installation being made.
To accomplish an attractive installation, you must:
1. Determine the need for side panels.
2. Determine side panel thickness.
3. Order matching side panels from the cabinet 
manufacturer. Be sure to provide the exact 
dimensions.
True Flush Installation
In a flush installation, 
the refrigerator doors
will align evenly with the
front face of adjacent cabinet
doors. The refrigerator blends
into the surrounding
cabinetry.
Semi-Flush Installation
These refrigerators
can also be installed
semi-flush into an enclosure
using the minimum cutout
width. The case trim creates a
frame around the opening.
Monogram built-in refrigerators and freezers can be
installed flush with typical 24-3/4
″ deep cabinetry.
When installed semi-flush, the case trim will conceal
slight gaps around the enclosure. The refrigerator or
freezer will project forward approximately 3/4
beyond the front face of surrounding cabinetry.
In any installation situation, a wide range of
appearance options can be accomplished through
the use of one or more trim kits. See trim kit
descriptions and appearance options on page 6.
Enclosure
Cutout and 
Product 
Dimensions
•To achieve a flush fit the finished cutout width must
be at least 36
″ wide.
•A semi-flush installation requires 35-1/2
″ min.
finished cutout width.
•The electrical and water locations must be located
as shown for either type of installation.
*36
″ Min. for a flush installation
35-1/2
″ Min. for a semi-flush installation
NOTE: Additional cutout width may be required when
side panels are used. Add side panel thickness to 
the finished cutout to calculate rough-in width. 
See installation examples on the following page.
Advance Planning
*Shipped at 84
″ installation height.
Can be adjusted to 83-1/2
″ or 84-1/2″ with grille panel kits.
0"
3/4"
36" 
Frame to Frame
84"*
26-1/4" 
Including 
Handle
35" 
Case 
Width
24-3/4" 
Case 
Depth
5"
10"
10"
3-1/2"
5"
3-1/2"
3-1/2"
*Finished Width
Wall View
Electrical
Area
2-1/2"
6"
5"
75" From Floor
to Bottom
of Electrical
Area
Water Supply
24-3/4" Total
Depth
84-1/2" max
83-1/2" min
Finished
Opening
DESIGN
INFORMA
TION